INSTALLATION
Checking Gas Connections (Cont.)
Installing Logs, Models CGS2718P, CGS2718N, CGS3124P,
CGS3124N, SGS3124P and SGS3124N
13
INSTALLATION
Continued
Pressure Testing Heater Gas Connections
1.Open equipment shutoff valve (see Figure 15).
2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.
3.Make sure control knob of heater is in the OFF position.
4.Check all joints from gas meter (natural gas) or propane/LP supply to equipment shutoff valve (see Figure 16 or 17). Ap- ply a commercial leak detection solution to all joints. Bubbles forming show a leak.
5.Correct all leaks at once.
6.Light heater (see Operating Heater, pages 15 through 17 [manu-
7.Turn off heater (see To Turn Off Gas to Appliance, page 17
Open
Equipment
Shutoff
Valve
Closed |
|
Figure 15 - Equipment Shutoff Valve |
|
Equipment Shutoff Valve | Control |
| Valve |
| Location |
Gas |
|
Meter |
|
Figure 16 - Checking Gas Joints (Natural Gas Only)
INSTALLING LOGS, MODELS CGS2718P, CGS2718N, CGS3124P, CGS3124N, SGS3124P AND SGS3124N
WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, reposition logs ac- cording to the log installation instructions in this manual. Flames contacting logs will create soot.
Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.
1.Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 18).
Back Log (#1)
Peg
Peg
Hole
Propane/LP Supply Tank
Equipment Shutoff Valve | Control |
| Valve |
| Location |
Figure 18 - Installing Back Log
Figure 17 - Checking Gas Joints (Propane/LP Gas Only)
For morevisit www..com