INSPECTING BURNERS

Pilot Assembly

Burner Flame Pattern

CLEANING AND MAINTENANCE REPLACEMENT PARTS

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT ASSEMBLY

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. The pilot is located on the back right hand side of the burner.

The thermocouple should be fully enveloped in the flame. The flame should not be lifting off of the thermocouple element.

If your pilot assembly does not meet these requirements:

Turn the adjustment screw marked pilot clockwise to decrease or counterclockwise to increase the flame to proper size (see Figure 20). Do not remove the adjustment screw.

see Troubleshooting, pages 13 through 15

Thermocouple

Pilot

Figure 19 - Correct Pilot Flame Pattern

T

Pilot

Adjustment

Screw

Figure 20 - Locating Pilot Adjustment Screw

BURNER FLAME PATTERN

Burner flames will be steady; not lifting or floating. Flames should go up through the middle of logset. Flames should not "spill" to the edges of the pan or sides of the logset.

Figure 21 shows a typical flame pattern. If burner flame pattern differs from that described:

turn appliance off (see To Turn Off Gas to Appliance, page 11)

see Troubleshooting, pages 13 through 15

CLEANING AND

MAINTENANCE

Keep the area around the log set clean and clear of debris.

Occasionally, you may use a soft bristle brush to clean logs.

Periodically inspect the air mixer and burner tube for foreign matter blocking the air inlet and flame holes.

Once every year a qualified agency or certified chimney sweep should examine and clean the venting system of the fireplace.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040. When calling DESA Inter- national, have ready

your name and address

model and serial numbers of your log set

how log set was malfunctioning

type of gas used (propane or natural gas)

purchase date

Usually, we will ask you to return the defective part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International at 1-866-672-6040. When calling DESA International, have ready

model number of your log set

the replacement part number

Figure 21 - Typical Flame Pattern

For morevisit www..com

901273-01D

Page 12
Image 12
Desa CPVSA18R, CPVSA24R, CVDA24R, CVDA30R, CVDA18R Inspecting Burners, Cleaning Maintenance, Replacement Parts

CVDA24R, CVDA30R, CPVSA18R, CPVSA24R, CVDA18R specifications

The Desa CVDA18R, CPVSA18R, CPVSA24R, CVDA24R, and CVDA30R are a series of advanced solutions designed to meet various heating and ventilation needs. These models come with a plethora of features, technologies, and characteristics that make them suitable for both residential and commercial applications.

The Desa CVDA18R, a heating powerhouse, boasts an impressive thermal output that ensures rapid heating across medium-sized spaces. It integrates advanced control systems allowing precise temperature regulation for enhanced comfort and energy efficiency. One of its standout technologies is the dual-fuel option, supporting both gas and electric heating, providing versatility depending on availability and preference.

Similarly, the CPVSA18R model stands out with its compact design, ideal for tight spaces without compromising on efficiency. It features a high-efficiency combustion system that maximizes heat production while minimizing fuel consumption. This model also includes an intelligent self-diagnostic system that monitors performance and alerts users to any potential issues, ensuring reliable operation.

The CPVSA24R takes things further with an increased heating capacity suitable for larger spaces. It combines sustainable technologies with user-friendly interfaces, allowing homeowners and businesses to manage their heating systems easily. Features such as programmable timers and remote access via smart devices add convenience in today's tech-driven world.

Next in the lineup, the CVDA24R focuses on improved air quality, equipped with advanced filtration systems that not only heat but also purify the air in living spaces. This model is particularly beneficial for those with allergies or respiratory concerns, ensuring a healthier indoor environment.

Lastly, the CVDA30R brings robust performance to the table, designed for expansive areas that demand high heating capacity. It incorporates sound-dampening technologies, making it one of the quietest units in its class. With a focus on energy efficiency, the CVDA30R meets or exceeds energy performance standards, helping users save on utility bills while contributing to a greener planet.

Overall, the Desa CVDA and CPVSA series exemplify cutting-edge heating technologies, offering a blend of efficiency, reliability, and user comfort. Each model caters to specific needs, ensuring that customers find the right fit for their unique heating challenges.