INSTALLATION

Continued

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater.SeeguidelinesunderCon- necting to Gas Supply, page 13.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using com- pressed air.

4.Check all joints of gas supply piping system. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 16).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for pro- pane/LP (see Figures 17 and 18). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open equipment shutoff valve (see Figure 16).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (Thermostat-Con- trolled Models) or to control valve (Manu- ally-Controlled Models) (see Figures 17 and 18). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, page 19 [manually-controlled models] or page 21 [thermostatically-controlled models]). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appli- ance, page 20 [manually-controlled models] or page 22 [thermostatically-controlled models]).

Equipment

Open

Shutoff

 

Valve

 

 

Closed

Figure 16 - Equipment Shutoff Valve

Propane/LP

Equipment

Supply Tank

Shutoff Valve

 

Thermostat Gas Valve or

 

Control Valve Location

Figure 17 - Checking Gas Joints

(Propane/LP Gas Models)

Equipment

Shutoff Valve

Gas Meter

Thermostat Gas Valve or

Control Valve Location

Figure 18 - Checking Gas Joints (Natural Gas Models)

113097-01C

www.desatech.com

15

Page 15
Image 15
Desa 24, 30 Test Pressures In Excess Of 1/2 Psig 3.5 kPa, Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa

CRL2718PA/NA, CRL3124PA/NA, CCL3018PA/NA, CCL3924PA/NA, CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB, CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB, 24", 30 specifications

Desa gas fireplaces are known for their innovative designs and advanced technologies, making them a popular choice among homeowners seeking both aesthetics and performance. Among the range of products, the models Desa 24", 30, CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB, CRL2718PA/NA, CRL3124PA/NA, and CCL3018PA/NA stand out due to their unique characteristics and features that enhance the home ambiance while providing efficient heating solutions.

One of the key features of these Desa models is their variable size offerings. With options like the 24" and 30" units, homeowners can choose the perfect fit for their space, whether it's a cozy corner or a focal point in the living room. The variety of sizes allows for flexibility in design, ensuring that each fireplace integrates seamlessly with the surrounding decor.

Moreover, these models are equipped with advanced heating technologies that improve energy efficiency. Many units feature dual fuel capabilities, allowing users to switch between natural gas and propane, which is ideal for adapting to different energy sources and preferences. This flexibility is coupled with a powerful output, providing substantial warmth while also being environmentally friendly.

The aesthetic appeal of Desa fireplaces cannot be overlooked. Models like CCL3018PTA/NTA and CCL3924PTA/NTA come with realistic flame effects that replicate a traditional wood-burning fireplace's ambiance without the hassle of keeping wood stocked. The captivating flame patterns and ember beds create a warm and inviting atmosphere, enhancing any living space.

In terms of safety and convenience, Desa fireplaces are designed with several features that ensure hassle-free operation. Most models include electronic ignition systems, allowing for easy start-up without the need for matchsticks or lighters. Additionally, many units come equipped with remote controls, enabling users to adjust settings such as flame height and heat output from the comfort of their seats.

The construction of Desa fireplaces also emphasizes durability and quality. Built with robust materials and carefully engineered components, these fireplaces are designed to withstand the test of time while maintaining high-performance standards.

Overall, the Desa lineup, featuring models such as CCL3930PTB/NTB, CRL2718PA/NA, and CRL3124PA/NA, brings together a perfect blend of efficiency, aesthetic appeal, and modern technology. The thoughtful design, user-friendly features, and versatile options make them a fantastic choice for anyone looking to upgrade their home heating solution while adding a touch of elegance to their interiors. With a Desa fireplace, homeowners not only invest in a reliable source of heat but also enrich their living environment with style and comfort.