Desa CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB, 24", 30 Product Identification, Unpacking

Models: CRL2718PA/NA, CRL3124PA/NA, CCL3018PA/NA, CCL3924PA/NA, CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB CCL3018PTA/NTA, CCL3924PTA/NTA, CCL3930PTB/NTB 24", 30

1 40
Download 40 pages 6.26 Kb
Page 5
Image 5

PRODUCT

IDENTIFICATION

Log Set

Burner

Piezo

Ignitor

Control Knob

Base

Grate

Figure 1 - Vent-Free Gas Log Heater

(Logs May Vary by Model, Seasonal Oak

Single Burner Model Shown)

UNPACKING

CAUTION: Do not remove the data plates from the grate as- sembly. The data plates contain

important product information.

1.

Remove logs and heater base assembly from

 

carton. Note: Do not pick up heater base as-

 

sembly by burners. This could damage heater.

 

Always handle base assembly by grate.

2.

Remove all protective packaging applied to

 

logs and heater for shipment.

3.

Check all items for any shipping damage. If

 

damaged, promptly inform dealer where you

 

bought heater.

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-free operation with flue damper closed. It has been tested and approved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANSI Z21.60) product by opening the flue damper (non-thermostat operation only).

SAFETY PILOT

This heater has a pilot with an Oxygen Deple- tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system re- quires no matches, batteries or other sources to light heater.

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight con- struction unless provisions are provided for adequate combus- tion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Todayʼs homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.