10.Feed thermostat wires from attic to furnace through 1/2" hole in ceiling wall plate.

11.Connect thermostat wires from attic to thermostat wires on furnace. Connect red wires together, then connect white wires together. Use wire nuts to make connections. IMPORTANT: Make sure thermostat wires do not touch combus- tion chamber.

Mounting the Thermostat to Wall

1.

Connect thermostat wires to the two

 

terminal screws on back of thermostat

 

(see Figure 6). Connect red wire to “R”

 

terminal. Connect white wire to “W”

 

terminal.

2.

Push any excess wire back through hole

 

in wall and plug hole with insulation

 

to prevent drafts. Drafts affect the ther-

 

mostat operation.

3.

Use thermostat base to mark mounting

 

screw locations.

4.

Drill proper-sized holes for wall anchors.

Wall

Anchors

.2

.3

 

.4

OFF

.5

 

.7

 

1.0

 

50

60

 

 

 

 

 

 

70

 

 

 

SOLID

 

 

80

90

 

 

 

 

 

STATE

 

 

 

 

 

 

 

 

50

60

 

 

 

IGNITION

 

70

 

 

 

 

 

80

 

 

 

 

 

90

 

 

 

 

 

 

Figure 7 - Mounting Thermostat to Wall

CONNECTING TO GAS SUPPLY

WARNING: A qualified ser- vice person must connect fur- nace to gas supply. Follow all local codes.

WARNING: Never connect furnace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

All piping must comply with local codes and ordinances or with the National Fuel Gas Code (ANS Z223.1 NFPA No. 54), whichever applies.

You can connect furnace to gas supply at front of furnace (inside) or at rear of furnace (outside).

Connecting Furnace to Gas Supply at Front of Furnace

1.Locate gas inlet pipe on lower, right front of furnace (see Figure 8).

2.Connect 3/8" NPT pipe or nipple to gas inlet pipe (see Figure 8). See Provid- ing Gas Piping to Furnace, pages 9 and 10, for correct gas pipe installation.

5. Attach thermostat to wall using screws

provided (see Figure 7).

WARNING: Unplug furnace before connecting to gas supply.

3/8" NPT Pipe or Nipple

Gas Inlet Pipe

White Wire

W

R

Red Wire

CAUTION: Use only new, black iron or steel pipe. Copper tubing may be acceptable in cer- tain areas. Check local codes. Use pipe large enough in diam- eter to allow proper gas volume to furnace. If pipe is too small, undue loss of pressure will oc- cur. Refer to chart on page 9.

Figure 8 - Connecting Gas from Inside of Room

Figure 6 - Connecting Thermostat Wires to Thermostat

CAUTION: Lightly apply pipe joint sealant to male threads be- fore connecting. Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Continued

201835

7

Page 7
Image 7
Desa DNV25NB, DNV40NB installation manual Connecting to GAS Supply, Mounting the Thermostat to Wall

DNV25NB, DNV40NB specifications

Desa DNV25NB and DNV40NB are contemporary heating solutions designed to meet the demands of modern residential and commercial spaces. Both models integrate advanced technologies, ensuring efficient performance while promoting sustainability and energy conservation.

The DNV25NB is a compact and versatile unit, making it ideal for small to medium-sized environments. It boasts a nominal heating capacity of 25 kW, providing a reliable source of warmth during colder months. One of its main features is the innovative heat pump technology that extracts energy from the environment, thereby lowering electricity consumption compared to traditional heating systems. The unit is also equipped with advanced inverter technology, which allows it to adjust its output according to the heat demand. This results in reduced energy usage and lower utility bills, making it an economical choice for homeowners or businesses aiming to minimize operational costs.

On the other hand, the DNV40NB is designed for larger spaces, offering a robust heating capacity of 40 kW. This model features a dual-stage compressor that enhances its heating efficiency. This technology ensures quick heating response, allowing it to maintain a consistent indoor temperature even in extreme weather conditions. Furthermore, the DNV40NB incorporates smart control systems that enable users to manage settings through a mobile app, providing convenience and remote monitoring capabilities.

Both models are characterized by their eco-friendly refrigerants, which contribute to reduced greenhouse gas emissions. The units are also designed with user-friendly interfaces featuring digital displays, making operation intuitive. Additional safety features, including over-temperature protection and anti-freeze modes, ensure safe usage while prolonging the lifespan of the units.

In terms of installation, both DNV25NB and DNV40NB are designed for easy integration into existing systems. Their compact design enables flexibility in placement without compromising aesthetics. With their reliable performance, energy efficiency, and user-centric technologies, the Desa DNV25NB and DNV40NB offer compelling solutions for those seeking sustainable heating alternatives. Overall, they represent a forward-thinking approach to climate control, combining performance with environmental responsibility.