Desa DNV25NB Installation, Continued, Connecting To Gas Supply, Mounting the Thermostat to Wall

Models: DNV25NB DNV40NB

1 30
Download 30 pages 45.99 Kb
Page 7
Image 7
Mounting the Thermostat to Wall

OWNER’S MANUAL

INSTALLATION

(Continued)

10.Feed thermostat wires from attic to furnace through 1/2" hole in ceiling wall plate.

11.Connect thermostat wires from attic to thermostat wires on furnace. Connect red wires together, then connect white wires together. Use wire nuts to make connections. IMPORTANT: Make sure thermostat wires do not touch combus- tion chamber.

Mounting the Thermostat to Wall

1.

Connect thermostat wires to the two

 

terminal screws on back of thermostat

 

(see Figure 6). Connect red wire to “R”

 

terminal. Connect white wire to “W”

 

terminal.

2.

Push any excess wire back through hole

 

in wall and plug hole with insulation

 

to prevent drafts. Drafts affect the ther-

 

mostat operation.

3.

Use thermostat base to mark mounting

 

screw locations.

4.

Drill proper-sized holes for wall anchors.

Wall

CONNECTING TO GAS SUPPLY Anchors

.2

.3

 

.4

OFF

.5

 

.7

 

1.0

 

50

60

 

 

 

 

 

 

70

 

 

 

SOLID

 

 

80

90

 

 

 

 

 

STATE

 

 

 

 

 

 

 

 

50

60

 

 

 

IGNITION

 

70

 

 

 

 

 

80

 

 

 

 

 

90

 

 

 

 

 

 

Figure 7 - Mounting Thermostat to Wall

CONNECTING TO GAS SUPPLY

Manual background WARNING: A qualified ser- vice person must connect fur- nace to gas supply. Follow all local codes.

Manual background WARNING: Never connect furnace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

All piping must comply with local codes and ordinances or with the National Fuel Gas Code (ANS Z223.1 NFPA No. 54), whichever applies.

You can connect furnace to gas supply at front of furnace (inside) or at rear of furnace (outside).

Connecting Furnace to Gas Supply at Front of Furnace

1.Locate gas inlet pipe on lower, right front of furnace (see Figure 8).

2.Connect 3/8" NPT pipe or nipple to gas inlet pipe (see Figure 8). See Provid- ing Gas Piping to Furnace, pages 9 and 10, for correct gas pipe installation.

5. Attach thermostat to wall using screws

provided (see Figure 7).

Manual background WARNING: Unplug furnace before connecting to gas supply.

3/8" NPT Pipe or Nipple

Gas Inlet Pipe

White Wire

W

R

Red Wire

Manual background CAUTION: Use only new, black iron or steel pipe. Copper tubing may be acceptable in cer- tain areas. Check local codes. Use pipe large enough in diam- eter to allow proper gas volume to furnace. If pipe is too small, undue loss of pressure will oc- cur. Refer to chart on page 9.

Figure 8 - Connecting Gas from Inside of Room

Figure 6 - Connecting Thermostat Wires to Thermostat

Manual background CAUTION: Lightly apply pipe joint sealant to male threads be- fore connecting. Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Continued

201835

7

Page 7
Image 7
Desa DNV25NB, DNV40NB installation manual Installation, Continued, Connecting To Gas Supply, Mounting the Thermostat to Wall