LIGHTING INSTRUCTIONS

INSTALLATION

Installing Logs (Cont.)

OPERATING FIREPLACE

For Your Safety Read Before Lighting Lighting Instructions

15

INSTALLATION

Continued

LIGHTING INSTRUCTIONS

Notches

Screws for

Mounting Screen

Figure 28 - Installing Fireplace Screen

OPERATING FIREPLACE

FOR YOUR SAFETY

READ BEFORE LIGHTING

OPERATING FIREPLACE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

FOR YOUR SAFETY WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

1.STOP! Read the safety information in column 1.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in OFF position.

Manual background WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

4.Press in and turn control knob clockwise Manual background to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise Manual background to the PILOT position. Press in control knob for five (5) seconds (see Figure 29).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

Manual background CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor Button

Flame Adjustment

Knob

 

O

O

L

 

IL T

O

AUTO

P

 

F

N

 

 

 

 

OFF

F

 

 

O

 

 

ON

 

HI

 

 

 

 

Selector Switch

Control Knob

Figure 29 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options)