Desa VSGF33PR Wiring Diagram, Specifications, Replacement Parts, Service Hints, Technical Service

Models: VSGF33PR EFS33NR

1 34
Download 34 pages 46.76 Kb
Page 23
Image 23
WIRING DIAGRAM

WIRING DIAGRAM SPECIFICATIONS REPLACEMENT PARTS SERVICE HINTS TECHNICAL SERVICE

23

WIRING DIAGRAM

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.

A

 

UT

O

OF

ON

F

 

Thermopile

SPECIFICATIONS

MODELS EFS33NR & VSGF33NR

Btu (Variable)

20,000/33,000

Type Gas

Natural Gas Only

Ignition

Piezo

Pressure Manifold

3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

10.5"

Minimum*

5"

Shipping Weight

122 lbs.

* For input adjustment

 

MODELS EFS33PR & VSGF33PR

Btu (Variable)

20,000/33,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Manifold

7.9" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

13"

Minimum*

11"

Shipping Weight

122 lbs.

* For input adjustment

 

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040. When calling DESA Inter- national, have ready

your name and address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information. When calling DESA International, have ready

model number of your fireplace

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low for propane/LP unit

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting.

If so, contact DESA International’s Technical Service Department at 1-866-672-6040.

You can also visit DESA International’s technical services web site at www.desatech.com.

SPECIFICATIONSFor moreMODELS EFS33NR & VSGF33NRMODELS EFS33PR & VSGF33PRREPLACEMENT PARTSvisit www.PARTS UNDER WARRANTYPARTS NOT UNDER WARRANTYSERVICE HINTS.comWhen Gas Pressure Is Too LowTECHNICAL SERVICEManual backgroundManual background