OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, etc., (see IMPORTANT

 

 

statement above)

 

2.

Low fuel supply

 

3.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor-causing products while heater is running

2.Refill supply tank

3.Locate and correct all leaks (see Check- ing Gas Connections, page 10)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 4)

 

2.

Low line pressure

2.

Contact local propane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 12)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 10)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 10)

Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air

1. Refer to Air for Combustion and Venti-

 

lation requirements (page 4)

www.desatech.com

105563

15

Page 15
Image 15
Desa FB-2B installation manual Observed Problem Possible Cause, Remedy

FB-2B specifications

The Desa FB-2B is an innovative and versatile piece of technology designed to cater to a wide range of applications, particularly in industries where performance, reliability, and efficiency are paramount. This ground-breaking product incorporates cutting-edge features and technologies that set it apart from its competitors.

One of the standout features of the Desa FB-2B is its robust construction, which ensures durability and longevity, even in demanding environments. This unit is built to withstand harsh conditions, making it an ideal choice for heavy-duty applications. The materials used in its manufacturing process have been carefully selected to guarantee resistance to wear and tear, as well as potential chemical exposure.

In terms of technology, the Desa FB-2B is equipped with advanced automation capabilities. This feature allows for seamless integration into existing systems, enabling users to operate it with minimal manual intervention. The automation technology enhances overall efficiency, as it reduces human error and optimizes performance.

Another significant aspect of the Desa FB-2B is its energy efficiency. The device has been engineered to consume minimal power while delivering maximum output. Its intelligent energy management system monitors usage and adjusts performance accordingly, ensuring that energy is used effectively without compromising on productivity.

The Desa FB-2B also boasts an intuitive user interface, making it accessible for operators of all skill levels. The user-friendly design facilitates quick adjustments and monitoring, enhancing overall operational effectiveness. Additionally, the interface is equipped with real-time data analytics, providing users with insights into performance metrics that could help drive further improvements.

Safety features are paramount in the design of the Desa FB-2B. It includes multiple fail-safes and alert systems to ensure that operators are informed of any potential issues before they escalate. This emphasis on safety contributes to a more secure working environment, making it suitable for applications where human interaction is a factor.

In summary, the Desa FB-2B is a remarkable piece of equipment that combines durability, advanced technology, energy efficiency, and user-friendly design. Its features make it an exceptional choice for industries that demand high-performance solutions, ensuring that users can rely on it for their operational needs. With its focus on safety and automation, the Desa FB-2B is truly a leader in its field.