INFRARED PROPANE/LP GAS HEATER

OPERATING

HEATER

Continued

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information

 

page 11, column 3.

 

2.

Make sure equipment shutoff valve

 

is fully open.

 

3.

Turn control knob clockwise

 

to the OFF position.

 

4.

Wait five minutes to clear out any

 

gas. Then smell for gas, including

 

near the floor. If you smell gas,

 

STOP! Follow “B” in the safety in-

 

formation page 11, column 3. If you

 

don’t smell gas, go to the next step.

5.

Press in and turn control knob coun-

 

terclockwise

to PILOT/IGN

 

position. Press in control knob for

 

five (5) seconds (see Figure 18).

 

Note: You may be running this heater

 

for the first time after hooking up to

 

gas supply. If so, you may need to press

 

in control knob for 30 seconds. This will

 

allow air to bleed from the gas system.

 

• If control knob does not pop up when

 

released, contact a qualified service

 

person or supplier for repairs.

6.

Release downward pressure on con-

 

trol knob and turn clockwise

 

to OFF position.

 

Figure 18 - Control Knob In The OFF Position

 

Ignitor Electrode

Thermocouple

Pilot Burner

 

Figure 19 - Pilot

TO SELECT

HEATING LEVEL

WARNING: When running heater, set control knob at LOW, MEDIUM, or HIGH locked posi- tions. Never set control knob be- tween locked positions. Poor combustion and higher levels of carbon monoxide may result.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

Slightlypressincontrolknobandturncoun-

terclockwise to the LOW, ME- DIUM, or HIGH positions (see Figure 20).

IMPORTANT: Release downward pres- sure while turning control knob. Control knob will lock at the desired position.

TO TURN OFF GAS TO

APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT/IGN position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions.

2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

7. Press in control knob and turn back

to PILOT/IGN. This will cause the

piezo ignitor to spark and light the

pilot gas. If needed, repeat steps 5

through 7 until pilot lights.

Note: If pilot does not stay lit, refer

to Troubleshooting, pages 15 through

17. Also contact a qualified service

person or gas supplier for repairs.

Until repairs are made, light pilot

with match. To light pilot with match,

see Manual Lighting Procedure.

8 . Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

Control

 

 

Knob

FB-3B

FB-5B

LOW

MED

HIGH

OFF

Figure 20 - Burner Patterns

12

107297

Page 12
Image 12
Desa FBS-3C, FB-5B, FBS-5C Operating Heater, Lighting Instructions, To Select Heating Level, To Turn OFF GAS to Appliance

FBS-3C, FB-5B, FBS-5C specifications

Desa FBS-5C, FB-5B, and FBS-3C represent an innovative line of advanced heating solutions that prioritize energy efficiency, user comfort, and environmental sustainability. These models showcase cutting-edge technology and an array of features designed to meet the diverse needs of residential and commercial spaces.

The Desa FBS-5C distinguishes itself with its high efficiency rating and sleek design. This model incorporates a robust heat exchanger that maximizes thermal efficiency, ensuring that energy consumption is minimized while delivering consistent warmth. The advanced digital thermostat allows users to set precise temperatures, while the programmable timing function enables enhanced control over heating schedules. Safety is paramount, and the FBS-5C features multiple safety mechanisms, including over-temperature protection and tip-over shutoff.

The FB-5B model is tailored for users seeking an effective heating solution without compromising on design. This model is compact and lightweight, making it ideal for smaller spaces or discrete installation. It incorporates advanced radiant heating technology that creates a comfortable warmth without the need for traditional forced air systems. Additionally, the FB-5B is equipped with a user-friendly control panel, allowing for easy adjustments and settings. Its low noise operation is particularly beneficial for environments where silence is essential, such as bedrooms or offices.

The FBS-3C model takes innovation a step further by integrating smart technology into its operating system. This model is Wi-Fi enabled, allowing users to control their heating remotely via smartphone applications. The adaptability of the FBS-3C ensures that it can seamlessly integrate with smart home systems, providing a convenient and user-friendly experience. Energy monitoring features enable users to track consumption and adjust settings to optimize efficiency, ultimately reducing heating costs and environmental impact.

In conclusion, Desa's FBS-5C, FB-5B, and FBS-3C models offer a range of features that cater to different heating needs. With their focus on efficiency, safety, and smart technology, these models exemplify the future of heating solutions. Whether for a cozy home setting or a commercial application, Desa's innovative approaches ensure warmth and comfort while promoting sustainability and user convenience.