OWNER’S MANUAL

FRESH AIR FOR

COMBUSTION AND

VENTILATION

Continued

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = ____________________ cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

_________________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater

___________________ Btu/Hr

 

 

 

 

 

Gas water heater*

___________________ Btu/Hr

Example:

 

 

 

Gas furnace

___________________ Btu/Hr

 

 

 

Gas water heater

 

40,000

Btu/Hr

Vented gas heater

___________________ Btu/Hr

 

Vent-free heater

 

+

18,000

Btu/Hr

Gas fireplace logs

___________________ Btu/Hr

Total

=

58,000

Btu/Hr

Other gas appliances* + __________________ Btu/Hr

 

 

 

 

 

Total

= __________________ Btu/Hr

 

 

 

 

 

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________________ Btu/Hr (maximum the space can support)

_________________ Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support) 58,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoin- ing room or add ventilation grills between rooms. See Ventilation Air From Inside Building, page 6.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6.

C.Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.

Continued

107297

5

Page 5
Image 5
Desa FBS-5C, FBS-3C, FB-5B Fresh AIR for Combustion Ventilation, Determining FRESH-AIR Flow for Heater Location

FBS-3C, FB-5B, FBS-5C specifications

Desa FBS-5C, FB-5B, and FBS-3C represent an innovative line of advanced heating solutions that prioritize energy efficiency, user comfort, and environmental sustainability. These models showcase cutting-edge technology and an array of features designed to meet the diverse needs of residential and commercial spaces.

The Desa FBS-5C distinguishes itself with its high efficiency rating and sleek design. This model incorporates a robust heat exchanger that maximizes thermal efficiency, ensuring that energy consumption is minimized while delivering consistent warmth. The advanced digital thermostat allows users to set precise temperatures, while the programmable timing function enables enhanced control over heating schedules. Safety is paramount, and the FBS-5C features multiple safety mechanisms, including over-temperature protection and tip-over shutoff.

The FB-5B model is tailored for users seeking an effective heating solution without compromising on design. This model is compact and lightweight, making it ideal for smaller spaces or discrete installation. It incorporates advanced radiant heating technology that creates a comfortable warmth without the need for traditional forced air systems. Additionally, the FB-5B is equipped with a user-friendly control panel, allowing for easy adjustments and settings. Its low noise operation is particularly beneficial for environments where silence is essential, such as bedrooms or offices.

The FBS-3C model takes innovation a step further by integrating smart technology into its operating system. This model is Wi-Fi enabled, allowing users to control their heating remotely via smartphone applications. The adaptability of the FBS-3C ensures that it can seamlessly integrate with smart home systems, providing a convenient and user-friendly experience. Energy monitoring features enable users to track consumption and adjust settings to optimize efficiency, ultimately reducing heating costs and environmental impact.

In conclusion, Desa's FBS-5C, FB-5B, and FBS-3C models offer a range of features that cater to different heating needs. With their focus on efficiency, safety, and smart technology, these models exemplify the future of heating solutions. Whether for a cozy home setting or a commercial application, Desa's innovative approaches ensure warmth and comfort while promoting sustainability and user convenience.