OWNER’S MANUAL

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install heater. Follow all local codes.

WARNING: Never install the

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP gas, do not install heater. Call dealer where you bought heater for proper type heater.

CLEARANCES TO

COMBUSTIBLES

(Vent-Free Operation Only)

WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining side and back walls.

Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The mini- mum clearances are shown in Figure 4. Measure from outermost point of stove top.

Minimum Wall and Ceiling Clearances (see Figure 4)

A.Clearances from outermost point of stove top to any combustible side wall should not be less than 12 inches.

B.Clearances from outermost point of stove top to any combustible back wall should not be less than 6 inches (In- cludes Corner Installations).

C.Clearances from the stove top to the ceiling should not be less than 48 inches.

heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

Ceiling

Front View

48"

Minimum

Side Wall

12"

 

12"

Side Wall

Minimum

 

 

Minimum

 

 

 

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

Top View

Back Wall

 

 

6 "

 

 

Minimum

 

12 "

12 "

 

Minimum

Minimum

Side Wall

 

 

Corner

Wall

 

 

6 "

Front of

 

Minimum

 

 

Stove Unit

Wall

6 "

 

Minimum

 

 

Side View

Ceiling

Side Wall

48"

Minimum

Back Wall

6"

Minimum

Floor

Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending on

Model)

Continued

 

104462

7

Page 7
Image 7
Desa FSVYD18P installation manual Installation, Check GAS Type, Clearances to Combustibles, Vent-Free Operation Only

FSVYD18P specifications

Desa FSVYD18P is an innovative, high-performance appliance designed to enhance various environments, whether in commercial settings, industrial applications, or even advanced home use. This model stands as a testament to the forward-thinking technology and robust features that define modern equipment.

One of the standout attributes of the FSVYD18P is its energy efficiency. Built with the latest in energy-saving technology, it minimizes power consumption without sacrificing performance. The optimized design ensures that it efficiently uses resources, catering to eco-conscious consumers and businesses alike. This feature not only contributes to lower utility bills but also supports sustainable practices.

In terms of functionality, the FSVYD18P is equipped with a state-of-the-art control system. The intuitive interface allows users to easily navigate settings and customize operations to fit specific needs. This adaptability is particularly important in environments where demands shift frequently, making it a versatile choice for diverse applications.

Durability is a key characteristic of the FSVYD18P. Designed using high-quality materials, this appliance can withstand the rigors of everyday use. Whether in a bustling commercial kitchen or an industrial workspace, the robust construction ensures longevity and reliability, reducing the need for frequent repairs or replacements.

The FSVYD18P also integrates advanced technologies that enhance its overall performance. Features such as smart sensors allow for real-time monitoring of performance parameters, ensuring that the appliance operates optimally. These sensors can automatically adjust settings based on usage patterns, further enhancing efficiency and user convenience.

Safety is another critical aspect of the FSVYD18P. The appliance incorporates multiple safety mechanisms that prevent malfunctions and ensure safe operation under various conditions. This commitment to safety not only protects users but also extends the life of the appliance.

Overall, Desa FSVYD18P encapsulates a rich blend of advanced technology, user-friendly features, and durable design. Its emphasis on energy efficiency, adaptability, and safety make it an ideal solution for those seeking high-quality performance in their equipment. This appliance is a reliable companion in achieving both operational excellence and environmental responsibility, making it a standout choice in its category.