CONNECTING TO GAS SUPPLY
WARNING: This appliance re- quires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator be- tween the heater and propane/LP supply.
Installation Items Needed
Before installing heater, make sure you have the items listed below.
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap
•tee joint
•pipe wrench
* A CSA |
valve with 1/8" NPT tap is an acceptable |
alternative to test gauge connection. Pur- |
chase the optional CSA |
inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure
20.Pointing the vent down protects it from freezing rain or sleet.
WARNING: Never connect heater to private
Back View
Back Stove
Panel
Product
Identification
Label
Side View
Front |
| Gas | |
of | Gas Inlet | Log | |
Stove | Heater | ||
Connection | |||
Unit |
| ||
Access |
| ||
|
|
Figure 19 - Gas Regulator Location and Gas Line Access Into Stove Cabinet
Propane/LP |
Supply Tank |
External |
Regulator |
Vent |
Pointing |
Down |
CAUTION: Use only new, black iron or steel pipe. Inter-
Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 21, SVYD18PR and FSVYD18PR series, or Figure 22, page 13, SVYD18P and FSVYD18P series).
IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliances.
Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.
equipment shutoff valve from your dealer. |
See Accessories, page 33. |
The gas inlet connection for the stove heater is located on the lower
19.Make sure gas log heater is secured to the stove cavity assembly.
The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14
Figure 20 - External Regulator With Vent Pointing Down
CSA
Shutoff Valve With 1/8" NPT Tap*
Approved Flexible Gas Hose (if allowed by local codes)
Gas |
|
Control | 3" Minimum |
From External Regulator (11" W.C.** to 14" W.C. Pressure)
Tee
Joint
Pipe Sediment
Nipple Trap
Cap
Figure 21 - Gas Connection (SVYD18PR and FSVYD18PR Series)