Desa FVFM27PR Operating Heater, To Turn Off Gas To Appliance, Manual Lighting Procedure

Models: FVFM27PR

1 28
Download 28 pages 11.36 Kb
Page 17
Image 17
OPERATING HEATER

OPERATING HEATER

Continued

safety information, column 1 on page 16. If you don’t smell gas, go to the next step.

6. Press in and turn control knob counter-

clockwise TO TURN OFF GAS to the PILOT position. Press in control knob for five (5) seconds (see Figure 22, page 17).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

• If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9. Slightly push in and turn control knob coun-

terclockwise  MANUAL LIGHTING to the ON position.

10. Wait one minute and switch selector switch to the ON position to light burner. Note: AUTO is only functional when using GWMT1, or GWMS2 optional accessories.

11. Set flame adjustment knob to any level between HI and LO.

Manual background CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Flame Adjustment Knob

 

AUTO

 

IH

 

O

 

 

 

 

 

OFF

 

 

N

F

 

 

 

 

 

F

 

ON

 

LO

O

IP

 

 

 

 

TOL

Ignitor Button

Selector

Control Knob

 

Switch

 

Figure 22 - Control Knob and Ignitor

Button Location (Shown as Supplied, No

Control Options)

Manual background WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Pilot Burner

Ignitor

Manual backgroundManual backgroundManual background Electrode

Figure 23 - Natural Gas Pilot

Pilot Burner

Ignitor

 

Electrode

Figure 24 - Propane/LP Gas Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise Manual background to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set se- lector switch in the OFF position to prevent draining battery.

Shutting Off Burner Only (pilot stays lit) You may shut off the burner and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise Manual background to the PILOT position.

2.Use remote control manual OFF button.

3.Set selector switch in the OFF position.

 MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 16.

2.Press control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions.

108382-01G

www.desatech.com

17

Page 17
Image 17
Desa FVFM27PR installation manual Operating Heater, To Turn Off Gas To Appliance, Manual Lighting Procedure