OPERATIon

Continued

4.Press in and turn control knob clockwise

to the OFF position.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 19. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counter-

clockwise to the PILOT position.

Press in control knob for five (5) seconds

(see Figure 32).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor button. This will light pilot.

The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 21.

8.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control knob coun-

terclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burner.

 

 

Ignitor Button

Control Knob

 

IH

 

 

N

O

 

O

F

AUTO

 

F

 

LO

TOLIP

OFF

 

 

ON

Flame Adjustment

Selector Switch

Knob

 

 

 

Figure 32 - Control Knob and Ignitor

Button Location (Shown as Supplied, No

Control Options)

11.Set flame adjustment knob to any level between HI and LO.

12.To leave pilot lit and shut off burners only:

turn control knob clockwise to the PILOT position, or use remote control manual OFF button, or set selector switch in the OFF position.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

WARNING: Make sure the selector switch is in the OFF positionwhenyouareawayfrom home for long periods of time. Fireplace will come on automatically with selector switch in the ON position.

Pilot Burner

Ignitor

Electrode

 

Figure 33 - Pilot (Propane/LP)

 

Ignitor

Pilot Burner

Electrode

Figure 34 - Pilot (Natural)

TO TURN OFF GAS

TO APPLIANCE

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to keep from draining the battery.

3.Close equipment shutoff valve (see Fig- ure 21, page 16).

20

www.desatech.com

113109-01G