OPERATIon
Continued
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 6 under Lighting Instructions, page 19.
2.Press control knob and light pilot with match.
3.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions, page 20.
Optional
REMOTE OPERATION
Note: All remote control accessories must be purchased separately (see Accessories, page 34). Follow instructions included with the remote control.
NOTICE: You must light the pilot before using the
After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 35).
Note: The burner may light if
IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.
Flame Adjustment Knob
IH |
|
|
|
|
| O |
|
|
| F | AUTO |
| N | F | |
LO | O | P | ON |
| |||
| TOL | ||
|
| I |
|
|
|
| OFF |
Control Knob | Selector Switch in Remote | |
Position (Optional Hand- | ||
in On Position | ||
Held Remote Control) | ||
|
Figure 35 - Setting the Selector Switch,
Control Knob and Flame Adjustment
Knob for Remote Operation
On/Off Series (Model HRC100)
Hold the control button on the
To Lock press both buttons on
To Unlock press both buttons together on
Control
Button Turns
Burners On
and Off
Figure 36 - On/Off
Control Unit (HRC100)
Thermostat Series (Model HRC200)
The
Manual Mode
1.Press the POWER and LOCK buttons together to turn on the
2.Press the MANU button to turn on the fireplace.
3.Press the POWER and LOCK buttons together to turn off the fireplace.
www.desatech.com | 21 |