Desa GA6050, GA6053, GA6052 installation instructions Fireplace Hood Installation Instructions

Models: GA6053 GA6050 GA6052

1 8
Download 8 pages 27.57 Kb
Page 1
Image 1
FIREPLACE HOOD

FIREPLACE HOOD

INSTALLATION INSTRUCTIONS

PART # GA6050 FLAT BLACK ENAMEL PART # GA6052 POLISHED PLATED BRASS PART # GA6053 ANTIQUE PLATED BRASS

Remove the contents of the fireplace hood kit. Check for any missing or damaged parts. If any parts are missing or damaged, promptly inform the dealer where you bought this kit.

Fireplace Hood Kit Contents:

1-Fireplace Hood (consists of center-hood sec- tion and two adjustable outer-hood sections)

4-Sheet Metal Screws

4-Masonry Screws

2-Mounting Brackets

NOTICE: Read this entire instruction sheet before installing the fireplace hood.

SIZING THE FIREPLACE HOOD TO THE FIREPLACE OPENING OR GLASS DOOR FRAME

The fireplace hood is adjustable from 28 to 48 inches. You must open hood wide enough to cover the entire fireplace opening. You can open hood wider if desired. For best appearance, make sure center section of hood is centered with the fireplace opening.

Follow the instructions below to properly size the fireplace hood.

1.Measure width of fireplace opening or glass door frame (see Measurement "A", Figure 1). Use work space below to figure proper size for fireplace hood.

Measurement "A" _______________

Subtract 24 inches

(width of hood center section) ___________

Subtotal = _______________

Divided by 2 _______________

Measurement "B" = _______________

Measurement "B" is the distance from the outside edges of center-hood section to outside edges of adjustable outer-hood sections (see Figure 2). When adjustable outer sections are extended to this measurement, hood will be correct size. The overall width of the hood will equal the width of the fireplace opening. If you have glass doors and would like the hood to hang beyond the edge of the door frame, add 1/2 inch to measurement "B". Make sure that hood provides room for opening doors.

2.If hood is brass, remove all protective film from brass.

3.Place center-hood section face down on a smooth, soft surface.

4.Measure in from outside ends of adjustable outer-hood sections. Place a piece of tape on bent-under flange of adjustable outer-hood sections to mark the distance of Measurement "B" (see Figure 3).

Measurement “A”

Fireplace Opening

Measurement “A”

Glass Door Frame

Figure 1 - Measurement "A"

Measurement "B"

Adjustable Outer-Hood

Fireplace Hood Kit Contents: Sections

Center-Hood Manual background

Section

Figure 2 - Measurement "B"

Adjustable Outer-

Manual background Hood Section

Measurement "B"

Tape

Figure 3 - Mark for Measurement "B"

Page 1
Image 1
Desa GA6050, GA6053, GA6052 installation instructions Fireplace Hood Installation Instructions, Fireplace Hood Kit Contents