Desa GL36CRP Operating Fireplace, Continued, To Turn Off Gas To Appliance, Lighting Instructions

Models: GL36CR GL36CLP

1 20
Download 20 pages 53.13 Kb
Page 12
Image 12
OPERATING FIREPLACE

OPERATING FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

1.Turn off the wall switch.

2.Turn off all electric power to the appliance if service is to be performed.

3.Remove control access panel.

4.Push in gas control knob and turn clockwise

TO TURN OFF GAS to OFF. Do not force.

5.Close shutoff valve (see Figure 14, page 9).

6.Replace control access panel.

Electronic models

FOR YOUR SAFETY

READ BEFORE LIGHTING

Electronic models WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot.

Do not light the pilot by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, column 1.

2.Set the thermostat to lowest setting (if applicable).

3.Turn off wall switch.

4.Open control access panel or louver.

5.Smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column 1. If you don’t smell gas, go to the next step.

6.Turn the main burner wall switch to the ON position for ignition. There will be a spark at the electrode. The electrode is located by main burner (see Figure 21).

7.Replace control access panel or louver once there is a flame at the burner.

8.If burner will not stay lit after several tries, flip the wall switch to OFF and call your service technician or gas supplier.

Figure 21 - Pilot

To

Main

Burner

From

 

 

Gas

E

A

Supply

Inlet Pressure Outlet Pressure

 

Figure 22 - Electronic Control Valve

TO TURN OFF GAS

TO APPLIANCE

1.Turn off all electric power to the appliance if service is to be performed.

2.Remove control access panel.

3.Close shutoff valve (see Figure 14, page 9).

12

www.desatech.com

112301-01D

Page 12
Image 12
Desa GL36CRP, GL36CLP Operating Fireplace, Continued, To Turn Off Gas To Appliance, Lighting Instructions, Pilot