Introduction
Models (V)GL36CR(P)/CL(P) are decorative gas fireplaces that use a millivolt gas control valve with millivolt ignition system. Models (V)GL36CR(P)E/CL(P)E use an electronic gas control valve with electronic ignition system.
These systems require a 6"
WARNING: This gas appli- ance must not be connected to a chimney flue servicing a solid fuel burning appliance.
If you are uncertain as to what gas your unit is approved and tested for, check rating plate on inside of fireplace opening or consult your local distributor of DESA products.
BEFORE YOU BEGIN
Before beginning the installation of your appli- ance, read these instructions through completely. This DESA appliance and its approved compo- nents are safe when installed according to this installation manual and are operated as recom- mended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY
CAUSE A FIRE HAZARD!
The DESA warranty will be voided by and DESA dis- claims any responsibility for the following actions :
A)Modification of the appliance or any of the components manufactured by DESA unless otherwise permitted by DESA.
B)Use of any component part not approved by DESA in combination with this appliance.
C)Installation and/or operation in a manner other than instructed in this manual.
D)The burning of anything other than the type of gas approved for use in this gas appliance.
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code, ANSI/NFPA
The installation must conform with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/NFPA 54 or with the current CAN/CGA B149 Installation Codes for Canada.
This appliance complies with ANSI Z21.50B- 1990 and
WARNING: Installation and repair should be done by a quali- fiedserviceperson. Theappliance should be inspected before use and at least annually thereafter by a qualified service person. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding etc. It is important that the control compartments, burnersandcirculatingairsystems be kept clean.
NOTICE: This appliance is not intended to be used as a primary source of heat.
Selecting Location
To determine the safest and most efficient location for your appliance, you must take into consider- ation the following guidelines:
1.The location must allow for proper clearances (see Clearances, page 6).
2.The location should be in a place where drafts, air conditioning ducts, windows or doors will not affect fireplace heat output.
3.A location that avoids the cutting of joists or roof rafters will make installation easier. Figure 2 shows a typical
Existing
Side
Wall
4" From Opening to Perpendicular Wall
Access Control Panel
Figure 2 - Typical Two Sided Fireplace
Installation