TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM POSSIBLE CAUSE | REMEDY |
Heater produces a clicking/tick- ing noise just after burner is lit or shut off
1.Metal expanding while heat- ing or contracting while cooling
1.This is common with most heat- ers. If noise is excessive, con- tact qualified service person
Heater produces unwanted odors 1. | Heater burning vapors from |
| paint, hair spray, glues, etc. |
| (see important statement |
| above) |
2. | Low fuel supply (propane/LP |
| gas only) |
3. | Gas leak. See Warning |
| statement above |
1.Ventilate room. Stop using odor causing products while heater is running
2.Refill supply tank
3.Locate and correct all leaks (see Checking Gas Connec- tions, page 13)
Heater shuts off in use (ODS op- | 1. Not enough fresh air is avail- | 1. | Open window and/or door for | |
erates) |
| able |
| ventilation |
| 2. | Low line pressure | 2. | Contact local propane/LP gas |
|
|
|
| company |
| 3. | ODS/pilot is partially | 3. | Clean ODS/pilot (see Cleaning |
|
| clogged |
| and Maintenance, page 19) |
|
|
|
| |
Gas odor even when control knob | 1. Gas leak. See Warning | 1. | Locate and correct all leaks | |
is in OFF position |
| statement above |
| (see Checking Gas Connec- |
|
|
|
| tions, page 13) |
| 2. | Control valve defective | 2. | Replace control valve |
Gas odor during combustion | 1. | Foreign matter between con- |
|
| trol valve and burner |
| 2. | Gas leak. See Warning |
|
| statement above |
1.Take apart gas tubing and re- move foreign matter
2.Locate and correct all leaks (see Checking Gas Connec- tions, page 13)
Moisture/condensation noticed on | 1. Not enough combustion/ven- | 1. Refer to Air for Combustion |
windows | tilation air | and Ventilation requirements |
|
| (page 5) |