Controlling Non-Motion Sensing Fixtures
❒When wiring to additional standard fixture only: Strip the motion sensor's red wire and connect to the standard light's black wire. Con- nect all white wires together. Total fixture ratings must not exceed 1000W (8.3 A).
NOTE: All wiring between fixtures should be run in accordance with the National Electrical Code through conduit or another acceptable means.
Contact a qualified electrician if there is any question as to the suitability of the system.
BLACK from
Switch to
BLACK from
JourneyMan®
❒This fixture is provided with a sensor rated for 1000W. Since the fixture is only rated 300W, 700W of additional load may be controlled by this sensor.
❒When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the marking which speci- fies the maximum lamp wattage for which the fixture is suitable.
❒Once you have selected the fixtures to be con- nected and determined their maximum ratings, add these ratings up. For instance, if you have 3 fixtures rated 100W, 150W, and 75W respec- tively, you have a total load of 325W.
RED from
JourneyMan®
to BLACK
from Fixture
WHITE from | WHITE from |
| |
Line to | Line to WHITE | (Standard) | |
WHITE from | from Fixture | ||
| |||
JourneyMan® |
|
|
Wiring to a Motion Light & Standard Fixture