Finish Mounting

Finish Mounting

Align the JourneyMan¨ base plate, gasket, and the junction box holes. Secure with mounting screws that fit your junction box.

If not installed on a weatherproof box or if the adaptor plate was used, caulk between the base plate and mounting surface with sili- cone weather sealant.

To avoid water damage and electrical shock, keep lamp holders aimed below horizontal.

Specifications

Range . . . . . . . . . . . . . . Up to 100 feet (30.5 m) with Range Boost On; up to 70 feet (21 m) with Range Boost Off. (Varies with sur- rounding temperature).

Sensing Angle . . . . . . . . Up to 270°

Fixture Load . . . . . . . . . Up to 300 Watts Maximum, Incandescent(Upto150Watts Maximum each lamp holder)

Sensor Load Capacity . . Up to 1000 Watts (8.3 amps) Maximum, Incandescent

Power Requirements . . . 120 VAC, 60 Hz

Operating Modes . . . . . TEST,AUTOandMANUAL OVERRIDE

Time Delay . . . . . . . . . . 1 , 5, 20 minutes

Sensitivity . . . . . . . . . . . Adjustable

DESA Specialty Productsª reserves the right to discontinue products and to change specifications at any time without incurring any obligation to in- corporate new features in products previously sold.