Universal Adaptor
If you are mounting the JourneyMan¨ fixture to a small rectangular box, you will need to use the universal adaptor as shown below. Other boxes may require the adaptor adjusted differently.
If you are using a standard octagon box, the adap- tor is probably not required.
Use these holes and the #8- 32 X 3/8" (10 mm) screws provided to secure the fixture.
Horizontal Box | |
| |
| screws |
Use these holes and the
Vertical Box
If the mounting holes in the fixture base still do not line up with the threaded holes in the univer- sal adaptor, you can (1) remove the adaptor and flip it over or (2) remove the other pair of knock outs in the fixture base.
Standard Wiring
CAUTION: If you have not already turned the power off at the breaker or fuse, do so now.
Make sure the gasket is in place before connect- ing any wires. You may find it convenient to use the wire hanger provided to hold the fixture to the junction box during the wiring process.
Connect the junction box wires to the fixture wires. Twist together and secure with wire connectors.
CAUTION: If you are not controlling additional fixtures from your JourneyMan¨ fixture, DO NOT connect the RED wire.
White to | Black to |
White | Black |
Junction
Box
Green ground |
|
| |
| Gasket | ||
wire to junction | RED, not | ||
| |||
box ground wire | used in most |
| |
| applications |
| |
|
|