INSTALLation
Continued
Mantel Clearances for
Installation
If placing custom mantel above
CAUTION: Close screens before operation of
If your installation does not meet the minimum clearances in Figure 7, you must:
• raise mantel to an acceptable height,
Conventional Installation of Blower Accessory
1.Install blower assembly per instruction sheet included in blower accessory kit.
2.Before replacing bottom of firebox, route blower power cord through hole in support bracket in bottom of firebox and through hole in side of firebox to grounded, three- prong 120 volt electrical outlet (see Fig- ure 8). Plug electrical cord into outlet.
3.Replace bottom of firebox.
NOTICE: A certified electrician must connect electricalwiringto duplex outlet for
OR
• remove mantel.
Note:
All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.
Facing material (above firebox) may be of combustible material, including decorative mantel ornaments.
Mantel Shelf
10"
8" 6"
2 1/2"
Electrical
Blower Outlet
Side
Opening
Firebox | 13" 16" 19" 21" |
Support Bracket
Opening
Blower Power
Cord
Screen Supplied
Firebox Hood
Must Be Used
at All Times
Figure 7 - Minimum Mantel Clearances
for
INSTALLING BLOWER ACCESSORY
You may install blower accessory GA3750A with conventional installation (below) or with
Figure 8 - Routing Blower Accessory Power Cord for Conventional Installation
1.Install blower assembly per instruction sheet included.
2.Before replacing bottom of firebox, re- move screw holding duplex outlet to sup- port bracket in bottom of firebox. Remove duplex outlet.
3.Clamp electrical cable into firebox through smallest hole using strain relief provided.
4.Route wires from electrical box through hole in side of heater and hole in support bracket (see Figure 9, page 9).
8 | www.desatech.com |