18
OPERATING FIREPLACE
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
OPERATING HEATER
Continued
Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the highest heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.
WARNING: Damper handle will be hot if heater has been running.
WARNING: Burners will come on automatically within one minute when the control valve is in the ON position after the pilot is lit.
1.STOP! Read the safety information, page 17 column 2.
2.Make sure equipment shutoff valve is fully open.
3.Set remote selector switch in the AUTO position (see Figure 34).
4.Press in and turn control knob clockwise to the OFF position (see Figure 34).
5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, page 17 column 2. If you don’t smell gas, go to the next step.
6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 34).
Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.
7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the rear of the front burner. If needed, keep pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.
Ignitor Button
Control Knob
Remote Selector Switch | AUTO MAN |
|
Figure 34 - Remote Selector Switch, Control Knob and Ignitor Button
8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
•If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.
9.Slightly push in and turn control knob counterclockwise to the ON position.
10.Press the on/off key on the remote control to turn on appli- ance main burner. Wait at least 5 seconds before setting desired flame height.
11.Press the up or down key until the small triangle is to the left of large flame icon at the top of LCD display (see Fig- ure 37, page 19). Press the left or right key to set the de- sired flame height.
CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.
Pilot Burner | Ignitor | Pilot Burner | Ignitor |
Electrode | |||
| Electrode |
|
|
Figure 35 - Pilot (Propane/LP) Figure 36 - Pilot (Natural)
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
Press on/off key on remote control and turn control knob
clockwise to the OFF position (see Figure 34).
Shutting Off Burners Only (pilot stays lit)
Press the on/off key on remote control or turn control knob
clockwise to the PILOT position.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 7 under Lighting Instructions, column 1.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11 under Lighting Instructions above.