Desa LSFG20NT, VSF30PT installation manual Natural Gas, Propane/LP

Models: VSF30PT LSFG20NT

1 48
Download 48 pages 45.06 Kb
Page 10
Image 10

Installation

Continued

CAUTION: For propane/LP gas, never connect heater di- rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install theexternalregulatorbetweenthe heater and propane/LP supply.

For propane/LP gas, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install the external regulator with the vent pointing down as shown in Figure 10. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.

Typical Inlet Pipe Diameters

20,000 Btu/Hr Models - 3/8" or greater

30,000 Btu/Hr Models - 1/2" or greater

Installation must include equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 11).

Propane/LP

External

Supply Tank

 

Regulator

Vent

Pointing

Down

Figure 10 - External Regulator With Vent

Pointing Down

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Sealant in pipe could result in clogged heater valves. Most flex gas tubing does not require sealant. Read instructions supplied with flex gas tubing.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

 

Rear View

 

Hole

 

 

 

Provided

 

 

 

in Rear

 

 

 

Surround

 

3/8" Male

Pipe Joint

Flex Gas

Sealant

Flare to NPT

Required

Line

Connector

(NPT End)

 

3/8" Male

 

 

Pressure

Flare

 

 

Regulator

to NPT

 

 

 

Connector

 

 

 

Pipe Joint

Equipment

 

Sealant

Shutoff

 

Required

Valve*

 

(NPT End)

3/8" NPT

 

Tee Joint

 

Pipe Nipple

Reducer

 

Natural Gas

Bushing

 

From Gas Meter

to 1/8"

 

(4" W.C. to 10.5"

NPT

 

W.C. Pressure)

1/8" NPT

 

Propane/LP

 

From External

Plug Tap

 

3" Min

Regulator

 

Test Gauge

 

(11" W.C. to 14"

Connection*

 

W.C. Pressure)

 

Cap Tee

Pipe

 

 

Joint

Nipple

 

Sediment Trap

Figure 11 - Gas Connection

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 21.

10

www.desatech.com

116307-01C

Page 10
Image 10
Desa LSFG20NT, VSF30PT installation manual Natural Gas, Propane/LP

VSF30PT, LSFG20NT specifications

The Desa VSF30PT and LSFG20NT represent two significant innovations in the HVAC (Heating, Ventilation, and Air Conditioning) industry, catering to diverse consumer needs and preferences.

The Desa VSF30PT is a powerful and efficient forced-air heater designed for residential and light commercial applications. One of its primary features is its high-efficiency output, providing a substantial heating capacity while consuming minimal energy. The unit is equipped with a robust heat exchanger that enhances its performance, ensuring optimal heat distribution throughout the space. A notable characteristic of the VSF30PT is its user-friendly digital thermostat, allowing for precise temperature control, which can significantly improve comfort levels and reduce energy consumption.

Additionally, the Desa VSF30PT incorporates advanced safety features, such as automatic shut-off protection in case of overheating or airflow obstruction. Its compact design makes it easy to install in tight spaces, providing flexibility in placement without compromising on effectiveness. The unit operates quietly, minimizing noise disturbances, which is especially important in residential settings.

On the other hand, the LSFG20NT is an innovative gas furnace that combines performance with energy efficiency. This model is equipped with a variable-speed blower motor that allows for consistent airflow and improved humidity control, making it an excellent choice for homeowners who prioritize comfort. Its multi-stage heating design ensures that the furnace operates at different levels according to the heating demand, optimizing energy usage and enhancing overall efficiency.

The LSFG20NT also features a modulating gas valve, which adjusts the burner output to provide just the right amount of heat for any given situation. This not only improves comfort but also contributes to significant energy savings over time. Furthermore, the LSFG20NT is designed with advanced filtration systems that improve indoor air quality by trapping dust, allergens, and other particles.

Both units showcase the latest technology in HVAC systems, emphasizing energy efficiency, safety, and user convenience. With their unique features and characteristics, the Desa VSF30PT and LSFG20NT stand out in the market, making them ideal choices for those seeking reliable and efficient heating solutions. Whether for residential or light commercial applications, these models promise performance that meets the demands of modern-day heating needs.