LOCATING HEATER

Manual background WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide

For convenience and efficiency, install heater

where there is easy access for operation, inspec- tion and service

in coldest part of room

CEILING

greater clearances from floor, ceiling and joining wall.

Manual background WARNING: Never install the heater

• in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, cloth-

 

ing or other flammable objects

 

are less than 36" from the front,

6" (15.2 cm)

Minimum Manual background From Sides Of Heater

Left

Side

FLOOR

36" (91.4 cm) Minimum

14"

 

(35.6 cm)

 

minimum

Right

 

 

Side

Residential Heaters:

2" Minimum To Top

Surface Of Carpeting,

Tile Or Other

Combustible Material

Garage Heaters:

18" Minimum To

Garage Floor

 

top or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

Manual background CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18" above floor

locate heater where moving vehicle will not hit it

Manual backgroundCAUTION:Thisheatercreates warmaircurrents.Thesecurrents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impu- rities (such as, but not limited to, tobaccosmoke,aromaticcandles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5. If high humid- ity is experienced, a dehumidifier may be used to help lower the water vapor content in the air.

Figure 4 - Mounting Clearances As

Viewed From Front of Heater

THERMOSTAT SENSING BULB

The thermostat sensing bulb is located on the lower rear panel of heater.

1.Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package.

2.Snap clamp into mounting hole as shown in Figure 5. Mounting hole is located in the center of lower back panel of heater. Make sure the thermostat sensing bulb is horizontal.

Clamp

Thermostat

Sensing Bulb

 

Figure 5 - Attaching Thermostat Sensing

Bulb

INSTALLING HEATER TO WALL

Methods For Attaching Heater To Wall Attach heater to wall in one of two ways:

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws into wall studs.

Attaching to Wall Anchor: This method allows you to attach mounting screws to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).