SPECIFICATIONS (W.C.)

INSTALLATION

Continued

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not instal in fireplace. Call dealer where you bought the appliance for proper type of appliance.

FUEL INLET WARNING: This appliance is equipped for (natural or pro- pane/LP) gas. Field conversion is not permitted.

INSTALLATION AND CLEARANCES

Figure 2 shows technical information regarding the installation of your gas log set. Please make sure all specifications shown are applicable before installation is attempted.

 

 

SPECIFICATIONS (W.C.)

 

 

 

FUEL INLET

MANIFOLD

 

 

PRESSURE

PRESSURE

 

 

 

Min.

Max.

 

 

NG

 

7"

10.5"

3.5"

 

LP

 

11"

14"

10"

 

Figure 2 - Technical Information Chart

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only

in a solid-fuel burning or UL127 factory-built fire-

place constructed of noncombustible material and

connected to a working flue. The fireplace chimney

must have a permanent vent opening to outside

with minimum openings shown in Figure 3.

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

 

MINIMUM FIREBOX SIZE

 

LOG

 

 

FRONT REAR* MIN. FLUE

SIZE HEIGHT DEPTH WIDTH WIDTH

SIZE

18"

 

20"

14"

25"

20.5"

6.5"

24"

 

20"

14"

29"

24.5"

6.5"

*Measured at 14" depth

 

 

 

Figure 3 - Sizes and Clearances

VENTING SPECIFICATIONS FOR

INSTALLATION

 

 

 

The fireplace chimney flue and vent must be draft-

ing properly. To check the vent for proper drafting:

Light a tightly rolled newspaper on one end and

place it at the inside front edge of the fireplace.

Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

The chimney flue damper must be fixed open to pro- vide a minimum of 32 square inch of free air opening at all times during operation of the log set. A damper clamp is included to secure the damper.

The minimum flue sizes shown in Figure 3 are based on a 6' chimney height using round pipe. Your minimum flue size will vary based on input rate and chimney height. Refer to the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 6.6 for details.

INSTALLING DAMPER CLAMP

Secure the damper stop clam to the edge of the

damper as shown in Figure 4. If for any reason

this clamp doesn't work on your fireplace, another

suitable clamp or permanent stop must be installed,

or the damper blade must be cut or removed.

Damper

 

Clamp

Damper

 

Damper

 

Clamp

 

Damper

Damper

Masonry

Manufactured

Fireplace

Fireplace

Figure 4 - Attaching Damper Clamp

INSTALLING REMOTE CONTROL

ACCESSORY BRACKET

If installing optional remote control accessory you

will need to install the remote accessory bracket

for the receiver.

 

Use screws provided to attach bracket to valve

bracket as shown in Figure 5.

Follow installation instructions included with

remote accessory.

 

Valve Bracket

 

Remote

 

Bracket

 

Figure 5 - Attaching Remote Bracket to

Valve Bracket