TROUBLESHOOTING
Continued
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
Dark orange flame in burner dur- | 1. | Not enough air | 1. | Check burner(s) for dirt |
ing burner combustion |
|
|
| and debris. If found, clean |
|
|
|
| burner(s) (see Cleaning and |
| 2. | Gas regulator defective |
| Maintenance, page 12) |
| 2. | Replace gas regulator | ||
| 3. | Control valve defective | 3. | Check manifold pressure |
|
|
|
| on control valve. Replace if |
|
|
|
| incorrect |
|
|
|
|
|
Slight smoke or odor during initial | 1. | Residues from manufacturing | 1. | Problem will stop after a few |
operation |
| processes and log curing |
| hours of operation |
|
|
|
|
|
Produces a whistling noise when | 1. | Turning control knob to HI | 1. | Turn control knob to LO |
burners are lit |
| position when burners are |
| position and let warm up for |
|
| cold |
| a minute |
| 2. | Air is gas line | 2. | Operate burners until air is |
|
|
|
| removed from line. Have gas |
|
|
|
| line checked by local natural |
|
|
|
| or propane/LP gas company. |
| 3. | Air passageways on heater | 3. | Observe minimum installation |
|
| blocked |
| clearances (see page 6) |
| 4. | Dirty or partially clogged | 4. | Clean burners (see Cleaning |
|
| burner orifice(s) |
| and Maintenance, page 12) or |
|
|
|
| replace burner orifice(s) |
|
|
|
|
|
White powder residue forming | 1. | When heated, vapors from | 1. | Heat turned off when using |
within burner box or on adjacent |
| furniture polish, wax, carpet |
| furniture polish, wax, carpet |
walls or furniture |
| cleaners, etc, turn into white |
| cleaners or similar products |
|
| powder residue |
|
|
|
|
|
|
|
Remote does not function | 1. | Battery is not installed. | 1. | Replace |
|
| Battery power is low |
| receiver and remote control |
www.desatech.com | 15 |