SPECIFICATIONS

OWNER’S MANUAL

SPECIFICATIONS

Output Rating

 

 

 

 

 

(Btu/Hr\kw)

35,000(10)

50,000(15)

70,000(20)

100,000(30)

150,000(44)

Fuel

 

Use Only Kerosene or No. 1 Fuel Oil

 

Fuel Tank Capacity

 

 

 

 

 

(U.S. Gal./Liters)

3.0/11.4

5.0/18.9

5.0/18.9

9.0/34

13.5/51.1

Fuel Consumption

 

 

 

 

 

(Gal. Per Hr./

 

 

 

 

 

Liters Per Hr.)

.28/1.1

.37/1.40

.52/1.97

.79/3.0

1.1/4.1

Electric Requirements

 

240 V/50 Hz (Same All Models)

 

Amperage

 

 

 

 

 

(Normal Run)

.8

1.0

1.0

1.2

1.2

Hot Air Output

 

 

 

 

 

(CFM/CMM)

140/4

205/5.8

225/6.4

425/12

500/14.2

RPM

1425

2850

2850

2850

2850

WIRING DIAGRAM

Power Plug

240 V/50Hz

Brown

1b

Blue

Green-Yellow

1

 

1a

Photocell

ON/Off Switch

Ignitor

Green-Yellow

 

 

 

 

 

Brown/White

Motor

Blue

Blue

White

White

Blue

Red

Black

Black

(1) (2)

(3) (4) (N) (5)

(6)

(7) (8)

Ignition Control

105787