Desa NTH50-2 Air Output, Air Intake, And Lint Filters, Pump Pressure Adjustment, Continued

Models: NTH35-2 NTH70-2 NTH50-2 NTH100-2 NTH150-2

1 28
Download 28 pages 42.13 Kb
Page 10
Image 10
AIR OUTPUT, AIR INTAKE, AND LINT FILTERS

PORTABLE FORCED AIR HEATERS

SERVICE

PROCEDURES

Continued

AIR OUTPUT, AIR INTAKE, AND LINT FILTERS

1.Remove upper shell (see page 8).

2.Remove filter end cover screws using 5/16" nut-driver.

3.Remove filter end cover.

4.Replace air output and lint filters.

5.Wash or replace air intake filter (see Preventative Maintenance Schedule, page 6).

6.Replace filter end cover.

7.Replace fan guard and upper shell.

IMPORTANT: Do not oil filters

PUMP PRESSURE

ADJUSTMENT

1.Remove pressure gauge plug and plas- tic cap (35/50/70,000 Btu/Hr Models only) from filter end cover.

2.Install accessory pressure gauge (part number HA1180).

3.Start heater (see Operation, page 5). Allow motor to reach full speed.

4.Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. See specifications below for correct pres- sure for each model.

5, Remove pressure gauge. Replace pres- sure gauge plug and plastic cap (35/50/ 70,000 Btu/Hr Models only) in filter end cover.

Air Intake Filter

Filter End

Fan Guard

Cover

Lint Filter

Air Output

Filter

Figure 13 - Air Output, Air Intake, and Lint Filters, 35/50/70,000 Btu/Hr Models

Air Intake Filter

Filter End

Fan Guard

Cover

 

Lint Filter

Air Output

Filter

Figure 14 - Air Output, Air Intake, and Lint Filters, 100/150,000 Btu/Hr Models

Pressure

 

 

Gauge

 

Pump

Plug

 

 

Pressure

Relief

 

Model

(PSI/Bar)

Valve

NTH35-2

2.9/0.200

 

NTH50-2

3.9/0.270

 

NTH70-2

4.9/0.338

 

NTH100-2

4.9/0.338

 

NTH150-2

5.5/0.380

Plastic Cap

 

 

Figure 15 - Pressure Gauge Plug and

Pressure

 

Plastic Cap Removal

Gauge

 

 

 

(35/50/70,000 Btu/Hr Models Shown)

 

 

Figure 16 - Adjusting Pump Pressure