Desa PCDM-36VB Conversion Labeling And Placement, Final Preparation, Close and latch door

Models: PCDM-36VB

1 6
Download 6 pages 22.62 Kb
Page 5
Image 5
CONVERSION LABELING AND PLACEMENT

CONVERSION LABELING AND PLACEMENT

1.Apply the English and French conversion labels over the top of the existing certification labels (see Figure 10). Existing certification labels are located on the lighting instruction plate inside the gas valve compartment area. With permanent ink, print the previous model number on the label in the space provided (see Figure 11).

2.After filling in the data required on the conversion informa- tion label (see Figure 12), affix it to the floor of the appliance where it is easily seen when the lower louver is removed.

French This Side

English This Side

Lighting Instruction Plate

Figure 10 - Applying English and French Conversion Labels over Existing Certification Labels on Lighting Instruction Plate

5

FINAL PREPARATION

1.Reinstall logs. Refer to Installing Logs, Lava Rock and Glow- ing Embers in owner’s manual.

2.Leak check the gas control and any connections you've made before operating the appliance. Refer to Checking Gas Con- nections in owner’s manual.

3.Close and latch door.

4.Replace screen and reinstall louver panels.

The conversion is now complete.

To operate your fireplace, refer to Operating Fireplace in your appliance owner’s manual.

FINAL PREPARATION WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct leaks at once.

3.Close and latch door. WARNING: Never use an open flame to check for a leak. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

4.Replace screen and reinstall louver panels. WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the

VENTED GAS FIREPLACE

Conversion Kit Model

Type of Gas

Previous Model #

CONVERSION INFORMATION LABEL

This appliance was converted on

 

 

to

 

gas

Day Month Year

with Kit No.

by

(name and address of organization making this conversion), which accepts the responsibility that this conversion has been properly made.

56060

106080-01

manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdic- tion. If the information in these instruction is not followed exactly, a fire, explosion, or production of carbon monoxide may result causing property dam- age, personal injury, or loss of life. The qualified service agency is responsible for the proper installa- tion of this kit. The installation is not proper and complete until the operation of the converted appli- ance is checked as specified in the manufacturer’s instructions supplied with the kit.

Figure 11 - Print Previous

Figure 12 - Conversion

Model Number on Conversion

Information Label

Labels

 

For moreThe conversion is now complete.Manual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background