REASSEMBLY POINTS
Continued
7.Tubular heating element must be flush against bracket (see Figure 14). This centers the ele- ment to the center hole in metal pan.
8.Fan must be located with set screw at back of and on flat of shaft (see Figure 15).
9.Heater is equipped with heat reflective tape. If loose or damaged, replace tape as shown in Figures 16 and 17. Tape edge should touch top of louver openings.
Figure 16 - Reflective Tape and Louvers
Figure 14 - Heating Element and Bracket
Figure 17 - Reflective Tape on All Louvers
Fan Set Screw
Back of, and Flat of Motor Shaft
Motor
Shaft
Figure 15 - Fan and Motor
www.desatech.com | 9 |