Desa PG15EA Troubleshooting, Continued, in a dark area, Disconnect element wires black and white

Models: PL15EA PG15EA PV15EA

1 12
Download 12 pages 42.89 Kb
Page 7
Image 7
in a dark area.

TROUBLESHOOTING

Continued

7.Replace removed plug in hole. Perform a trial operation.

8.If repeated resetting of the thermal limit switch is required, have the product serviced by an authorized service center.

OBSERVED FAULT

Tubular heating element heats up but no rush of warm air is felt at outlet vents

Rotate fan by hand to determine if fan

rotates easily

OBSERVED FAULT

Motor starts and runs but cool air is felt

Does tubular heating element heat up?

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

WARNING:

 

WARNING:

 

Hot Surface!

 

Hot Surface!

1 Look for defective

3

Check for blocked

 

tubular heating

 

air intake openings

 

 

 

element

 

 

 

 

 

 

2Open tubular heating element

Fan is difficult

to rotate

1Fan or motor obstructed

2 Dry motor bearing

Test Procedure

Fan rotates easily

by hand

3 Open motor coil

Test Procedure

1. Look for Defective Tubular Heating

Element

After approximately 2 minutes the tubular heat-

ing element should glow a dull red when placed

in a dark area.

2. Open Tubular Heating Element

Disconnect element wires (black and white).

1.Fan or Motor Obstructed

Remove obstruction. Clean heater.

2.Dry Motor Bearing

If the fan is difficult to turn, then motor bearings are defective. Bearings are permanently lubricated, therefore motor should be replaced.

3. Open Motor Coil

Disconnect motor wires (black and white). Attach the ohmmeter leads to the motor wire terminals. Using the 0 to 200 ohm scale, measure the resis- tance of the motor coil. If the resistance is not approximately 6.0 to 6.4 ohms at 73° F, the motor is defective and should be replaced.

Note: Resistances may vary due to motor temperature.

Figure 6 - Testing Motor

Attach the ohmmeter leads to the element wire

terminals. Using the 0 to 200 ohm scale, measure

the resistance of the element. If the resistance is

not 8.5 to 11 ohms at 73° F the element is defective

and should be replaced. Note: Resistances may

vary due to element temperature.

3. Check for Blocked Air Intake Openings

Check for blockages around vent openings at bot-

tom of heater (see Figure 5, page 6).

Figure 7 - Testing Heating Element

115423-01A

www.desatech.com

7

Page 7
Image 7
Desa PG15EA, PV15EA Troubleshooting, Continued, in a dark area, Disconnect element wires black and white, Testing Motor