PRODUCT IDENTIFICATION

Top

Shell

Thermocouple

Ignitor

Electrode

Burner Tube

Piezo Ignitor Button

OFF

 

LO

HI

MED

 

Valve Inlet

Control Knob

Base

 

 

Hose/Regulator

Assembly

Figure 1 - Product Identification

UNPACKING

1.Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to valve inlet and hose/regulator assembly) for storage.

2.Remove all items from carton.

3.Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.

THEORY OF OPERATION

The Fuel System: The hose/regulator assembly attaches to the propane gas supply. This provides fuel to the heater.

The Ignition System: The piezo ignitor lights the burner fuel supply.

The Automatic Control System: This system causes the heater to shut down if the flame goes out.

PROPANE SUPPLY

Propane gas and propane tank(s) are to be furnished by the user.

Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2. Your local library or fire department will have this booklet.

The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount.

1.The amount of liquid propane gas in tank(s)

2.The temperature of tank(s)

The chart below shows the minimum number of 45 kg (100 lb) tanks needed to run the heater. Connect tanks together with a manifold.

Average Temperature

Number Of Tanks

°C (°F) At Tank Location

45 kg (100 lb)

16° (60°)

1

4° (40°)

1

0° (32°)

1

-6.7° (20°)

1

-12° (10°)

2

-18° (0°)

2

Less gas is vaporized at lower temperatures. Your local propane gas dealer will help you select the proper supply system.

VENTILATION

WARNING: Provide at least a .23 m2 (2.5 ft2) opening of fresh, outside air while running heater. If proper fresh, outside air ventilation is not pro- vided, carbon monoxide poisoning can occur. Pro- vide proper fresh, outside air ventilation before running heater.

For more information, visit www.desatech.com

104781-01D

Page 3
Image 3