FUELS

115,000 Btu/Hr H.S.I. Series

PORTABLE FORCED AIR HEATER

FUELS

THEORY OFWARNING: Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.

Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in a clogged fuel filter and/or nozzle.

THEORY OF

OPERATION

The Fuel System: The air pump forces air through the air line. The air is then pushed through the nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.

The Air System: The motor turns the fan. The fan pushes air into and around the

combustion chamber. This air is heated and provides a stream of clean, hot air.

The Ignition System: The ignition con- trol assembly provides power to the ignitor. This ignites the fuel/air mixture in the com- bustion chamber.

The Flame-Out Control System: This system causes the heater to shut down if the flame goes out.

IMPORTANT: Use a KEROSENE ONLY storage container. Be sure storage container is clean. Foreign matter such as rust, dirt, or water will cause the ignition control assembly to shut down the heater. Foreign matter may also require you to clean fuel system often.

VENTILATION

VENTILATION Follow the minimum fresh, outside air ventilation require- ments. If proper fresh, outside air ventilation is not provided, car- bon monoxide poisoning can oc- cur. Provide proper fresh, out- side air ventilation before run- ning heater.

Provide at least a three-square-foot opening of fresh, outside air for each 100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.

Example: A 115,000 Btu/Hr heater re- quires one of the following:

a two-car garage door (16 feet wide open- ing) raised three inches

a single-car garage door (9 feet wide opening) raised five inches

two 30 inch wide windows raised eight inches

 

Combustion Chamber

Ignitor

Motor

Air Pump

 

 

 

Air Intake

 

 

 

Fan

 

 

 

Filter

Clean

 

 

 

Cool

Heated

 

 

 

 

 

 

Air

Air Out

 

 

 

 

 

 

 

In

 

 

 

 

Air

 

 

 

 

Output

 

 

 

 

Filter

Fuel

Nozzle

Fuel

Air Line

Ignition Control

Tank

 

Filter

To Burner

Assembly

 

 

 

Air For Fuel System

 

Air For Combustion

Fuel

 

 

And Heating

 

 

 

 

Figure 3 - Cross Section Operational View