Desa R115T, B115T Pump Rotor, Ignition Control Assembly, Procedure if Rotor is Binding, Continued

Models: B115T R115T REM115T

1 16
Download 16 pages 61.42 Kb
Page 10
Image 10
PUMP ROTOR

115,000 Btu/Hr H.S.I. Series

PORTABLE FORCED AIR HEATER

SERVICE

PROCEDURES

Continued

PUMP ROTOR

(Procedure if Rotor is Binding)

1.

Remove upper shell (see page 7).

2.

Remove filter end cover screws using

 

5/16" nut-driver.

3.

Remove filter end cover and air filters

 

(see Figure 16).

4.

Remove pump plate screws using 5/16"

 

nut-driver.

5.

Remove pump plate.

6.

Remove rotor, insert, and blades.

7.

Check for debris in pump. If debris is

 

found, blow out with compressed air.

8.

Install insert and rotor.

9.

Check gap on rotor. Adjust to .003"/

 

.004" if needed (see Figure 17).

 

Note: Rotate rotor one full turn to in-

 

sure the gap is .003"/.004" at tightest

 

position. Adjust if needed.

10.

Install blades, pump plate, air filters,

 

and filter end cover.

11.

Replace fan guard and upper shell.

12.

Adjust pump pressure (see page 7).

 

Note: If rotor is still binding, proceed

 

as follows.

13.

Perform steps 1 through 6 above.

Blade

Pump Plate

Air Intake Filter

Filter End

Cover

Insert

Rotor

Air Output

Filter

Fan Guard

Figure 16 - Rotor Location

Gap Adjusting Screw

Blade

.003"/.004" Gap Measured With Feeler Gauge

Rotor

Gap Adjusting Screw

IGNITION CONTROL

ASSEMBLY

(Procedure for Replacing Fuse)

(Procedure if Rotor is Binding) WARNING: High Voltage

1.Unplug heater.

2.Remove side cover screws (4) using 5/16" nut-driver to expose ignition con- trol assembly.

3.Remove fuse cover (see Figure 19).

4.Remove fuse from fuse clips.

5.Replace fuse with fuse of the same type and rating (GMA-10). Do not substi- tute a fuse with a higher current rating.

6.Replace fuse cover.

7.Replace side cover.

Fuse

Fuse

Clips

Cover

 

 

Fuse

Figure 19 - Replacing Fuse

Figure 17 - Gap Adjusting Screw Locations

14.

Place fine grade sandpaper (600 grit)

 

 

on flat surface. Sand rotor lightly in

 

 

“figure 8” motion four times (see Fig-

Sandpaper

 

ure 18).

15.

Reinstall insert and rotor.

 

16.

Perform steps 10 through 12 above.

 

Figure 18 - Sanding Rotor

10

104193

Page 10
Image 10
Desa R115T Pump Rotor, Ignition Control Assembly, Procedure if Rotor is Binding, Procedure for Replacing Fuse, Continued