Desa REM30LP Assembly, Propane Supply, Installation, Average Temp F, No. Of Tanks, pound

Models: REM30LP

1 16
Download 16 pages 36.01 Kb
Page 4
Image 4
ASSEMBLY

4

ASSEMBLY PROPANE SUPPLY INSTALLATION

ASSEMBLY

1.Remove screw from top of fan guard. Discard screw.

2.Insert nut clip (provided with handle) with flat side facing up through slot in top of shell. Align holes in nut clip with screw hole behind slot in top of shell. (see Figure 4).

3.Place handle over hole and clip. Insert two screws (provided with handle) through handle and tighten into shell. Make sure rear screw goes through shell and into fan guard. Tighten screws firmly.

Remove

Screw

Figure 3 - Removing Screw from Top of Fan Guard

Flat Side Facing Up

Nut Clip

Shell

Slot

Figure 4 - Installing Nut Clip

Screws

Handle

Nut Clip PROPANE SUPPLY

Rear of

Heater

Figure 5 - Attaching Handle

PROPANE SUPPLY

Propane gas and propane tank(s) are to be furnished by the user.

Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2. Your local library or fire department will have this booklet.

The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount:

1.The amount of propane gas in tank(s)

2.The temperature of tank(s)

This heater is designed to operate with a minimum 20-pound propane tank. You may need two or more tanks or one larger tank in colder weather. Use a 100-pound tank for longer operation or in very cold weather. Less gas is vaporized at lower temperatures. Your local propane gas dealer will help you select the proper supply system. The minimum surrounding air temperature rating for each heater is -20°F (-29°C).

Average Temp (°F)

No. Of Tanks

At Tank Location

(100-pound)

40°

1

32°

1

20°

1

10°

1

1

-10°

2

-20°

2

INSTALLATION

Average Temp (°F) WARNING: Review and understand the warnings in the Safety Information section, page 2. They are needed to safely operate this heater. Follow all local codes when using this heater.

No. Of Tanks WARNING: Test all gas piping and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

1.Provide propane supply system (see Propane Supply).

2.Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL fitting counterclockwise into threads on tank. Tighten firmly using wrench. IMPORTANT: Position regula- tor so that hose leaving the regulator is in a horizontal position (see Figure 6, page 5). This places the regulator vent in the proper position to protect it from the weather.

At Tank Location(100-pound)INSTALLATIONManual backgroundManual backgroundManual backgroundManual backgroundFor moreManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

104163-01H

Page 4
Image 4
Desa REM30LP owner manual Assembly, Propane Supply, Installation, Average Temp F, No. Of Tanks, At Tank Location, pound