Desa REM30LP owner manual Service Procedures, Continued, Ignitor

Models: REM30LP

1 16
Download 16 pages 36.01 Kb
Page 9
Image 9
IGNITOR

SERVICE PROCEDURES

Continued

5a. If replacing fan, remove old fan and discard. Go to step 7 below.

5b. If cleaning fan, use soft cloth moistened with kerosene or solvent.

6.Dry fan thoroughly.

7.Place fan onto motor shaft. Make sure set screw contacts flat sur- face on motor shaft. Tighten set screw firmly (40-50 inch-pounds).

8.Place motor and fan guard into rear of heater shell. Make sure power cord is properly located (see Figure 12, page 8).

9.Insert three screws through heater shell and into fan guard. Tighten screws firmly.

IGNITOR

1.Remove motor and fan guard from heater (see Motor, page 8, steps 1 and 2).

2.Remove black ignitor wire from piezo ignitor. Access ignitor wire through underside of heater base (see Figure 13). Push wire up through notch in filler panel.

3.Remove ignitor mounting screw from rear head using nut-driver or standard screwdriver (see Figure 14).

4.Remove ignitor from rear head.

5.Install new ignitor. Attach ignitor to rear head with ignitor mounting screw.

Piezo Ignitor Manual background

Ignitor Wire

Underside

of Heater

 

Figure 13 - Removing Ignitor Wire from Piezo Ignitor

Mounting Screw

Ignitor

SERVICE PROCEDURES

9

6.Run ignitor wire from new ignitor through notch in filler panel. Attach ignitor wire to piezo ignitor.

7.Set gap between ignitor electrode and target plate to .17" (see Figure 15).

Manual background WARNING: Make sure heater is disconnected from propane supply. Heater could ignite causing severe burns.

8.Test for spark. Push piezo ignitor button and watch for spark between ignitor electrode and target plate.

9.Place motor and fan guard into rear of heater shell (see Motor, page 8, steps 9 and 10).

Ignitor Electrode

Gap

Area

Figure 15 - Clearance between Ignitor Electrode and Target Plate

Figure 14 - Removing Ignitor Mounting Screw and Ignitor

Manual backgroundManual backgroundManual backgroundFor more information, visit www.desatech.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

104163-01H

Page 9