SPECIFICATIONS

7.Replace spark plug into combustion chamber. Tighten spark plug mount- ing nut finger tight onto spark plug threads. Use 11/16" socket to hold spark plug mounting nut. Tighten spark plug to spark plug mounting nut using 13/16" spark plug socket.

8.Attach spark plug cable to spark plug.

9.Replace fan (see page 10).

10.Replace fan guard and upper shell.

SPECIFICATIONS

12

Spark Plug

Mounting Nut

Combustion

Chamber

Figure 14 - Spark Plug Mounting Nut Location

45/80 Front ViewLP-PFA/P 018

Output Rating (BTU/Hr)

80,000

150,000

Fuel

Propane Vapor Only For All Models

Fuel Consumption

 

 

Gallons/Hour

0.9

1.6

Pounds/Hour

3.7

7.0

Supply Pressure To Regulator

 

 

Minimum (for purposes

 

 

of input adjustment)

10 psi

10 psi

Maximum

Tank Pressure For All Models

Regulator Outlet Pressure

 

 

(Factory Preset)

11" WC

12.5" WC

Manifold Pressure

9" WC

9.8" WC

Hot Air Output

 

 

(CFM Approx)

350

550

Motor

3,400 RPM, 1/10 HP

3,430 RPM, 1/8 HP

Electric Input

120 V/60 Hz

120 V/60 Hz

Amperage

3

2.2

Ignition

Direct Spark, Interrupted Type For All Models

Spark Plug Gap (Inches)

.06/.08

N/A

Ignitor Gap (Inches)

N/A

.13/.15

Weight (Pounds)

 

 

Heater

26

24

Shipping

30

35

Size - L x W x H (Inches)

291/2 x 12 x 181/2

361/4 x 141/2 x 20

099162