UNPACKING
THEORY OF OPERATION
1.Remove all packing items applied to heater for shipment. Keep plastic cover caps (attached to inlet connector and hose/regulator assembly) for storage.
2.Remove all items from carton.
3.Check all items for shipping damage. If heater is damaged, promptly inform dealer where you bought heater.
The Fuel System: The hose/regulator assembly attaches to the propane gas supply. The propane gas moves through the solenoid valve and out the nozzle.
The Air System: The motor turns the fan. The fan pushes air into and around the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The direct spark ignitor (DSI) sends voltage to the spark plug/ignitor. The spark plug/ignitor ignites the fuel and air mixture.
The Safety Control System: This system causes the heater to shut down if the flame goes out.
Combustion |
| Fan | ||
Chamber |
| |||
Nozzle |
| Motor | ||
|
|
| ||
|
|
| ||
|
|
|
| |
|
|
|
|
|
Clean |
|
Heated |
|
Air Out |
|
(Front) | Cool Air In |
| |
| (Back) |
Spark Plug/Ignitor |
|
| Power |
|
| Cord | |
| DSI | Solenoid |
|
| Valve |
| |
|
|
| |
|
| On/Off Switch | Hose/Regulator |
|
| Assembly | |
|
|
| |
Air For Combustion |
| Fuel |
|
And Heating |
|
|
|
Figure 3 - Cross Section Operational View (80,000 BTU/Hr Model Shown) | |||
45/80 LP SIDE |
|
Note: Some parts are located differently on some models.
5