Desa ROPANE CONSTRUCTION HEATERS Maintenance Preventative Maintenance Schedule, How Often, How To

Models: ROPANE CONSTRUCTION HEATERS

1 16
Download 16 pages 37.74 Kb
Page 9
Image 9
MAINTENANCE

MAINTENANCE

PREVENTATIVE MAINTENANCE SCHEDULE

!WARNING

Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.

1.Keep heater clean. Clean heater annually or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth.

2.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once.

3.Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace.

4.Have heater inspected yearly by a qualified service agency.

5.Keep inside of heater free from combustible and foreign objects.

!WARNING

Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and electrical shock can occur.

Item

Fan

Air Sensing

Switch

(80,000 BTU/Hr

Model Only)

Spark Plug

(80,000 BTU/Hr

Model Only)

How Often

Clean every 500 hours of operation or as needed.

Clean every 500 hours of operation or as needed.

Clean and regap every 500 hours of operation or replace as needed.

How To

See Fan, page 10.

See Air Sensing Switch, page 11.

See Spark Plug, page 11.

9

099162

Page 9
Image 9
Desa ROPANE CONSTRUCTION HEATERS owner manual Maintenance Preventative Maintenance Schedule, How Often, How To