Desa SBVBN(D) installation manual Installing Optional Wall Mount Switch GWMS2, Will occur

Models: SBVBN(D)

1 36
Download 36 pages 52.57 Kb
Page 15
Image 15

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Checking Gas Connections (Cont.)

Installing Optional Wall Mount Switch - GWMS2

Installing Optional Wall Mounted Thermostat - GWMT1

15

CAST IRON STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

Pressure Testing Burner System Gas

Connections

1.Open equipment shutoff valve (see Figure 30, page 14).

2.Open propane/LP supply tank valve for propane/LP burner system or main gas valve located on or near gas meter for natural gas burner system.

3.Make sure control knob of burner system is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 31 for propane/LP or Figure 32 for natural, page 15). Apply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light burner system (see Lighting Instructions, page 19). Check all other internal joints for leaks.

6.Turn off burner system (see To Turn Off Gas to Appliance, page 19).

Equipment

Propane/LP

Shutoff

Supply Tank

Valve

 

Gas Valve

 

Figure 30 - Checking Gas Joints for Propane/LP Gas Burner System (Amity™ Model Shown)

INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2

1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 33. If wires are not connected as shown, the switch will not work.

2.Route the 25 ft. wire through openings provided on the sides of the burner system to a convenient location to mount your switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install the wall switch and cover in the wall.

To Control Switch or

Optional Accessory

Figure 33 - Control Valve Terminals

INSTALLING OPTIONAL WALL MOUNTED THERMOSTAT - GWMT1

WARNING: Installation must be done by a qualified installer familiar with low voltage wiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard

Gas Valve

Equipment Shutoff Valve

Gas Meter

will occur.

1.Open lower door panel. The valve is attached to the underside of the burner system assembly.

2.Disconnect from the valve the wires running from the ON/ OFF switch.

3.Connect one terminal of the wire for the wall thermostat to the THTP terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire termi- nals are in the positions on the unit as pictured in Figure 33. If wires are not connected as shown the thermostat will not work.

Figure 32 - Checking Gas Joints for Natural Gas Burner System (Amity™ Model Shown)

For morevisit www..com

112127-01A

Page 15
Image 15
Desa SBVBN(D) Installing Optional Wall Mount Switch GWMS2, Installing Optional Wall Mounted Thermostat GWMT1, Will occur