Desa SCIVFR, SCIVFB Inspecting Burners, To Turn Off Gas To Appliance, Manual Lighting Procedure

Models: SCIVFG SCIVFC SCIVFR SCIVFB

1 32
Download 32 pages 46.37 Kb
Page 21
Image 21
INSPECTING BURNERS

OPERATING HEATER

Continued

INSPECTING BURNERS

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

 

 

1.

Press in and turn control knob clockwise

Clockwise

to the HIGH position.

2.

Turn the control knob clockwise Clockwise

to the PILOT position.

3.

Press in control knob and turn clockwise

Clockwise

to the OFF Position.

Shutting Off Burners Only (pilot stays lit)

1.

Turn the control knob clockwise Clockwise

to the HIGH position.

2.

Press in and turn control knob clockwise

Clockwise to the PILOT position.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, pages 19 and 20.

2.Pilot is located inside stove cavity attached to burner. Lift off top grate to allow access to pilot.

3.Depress control knob and light pilot with match.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

5.Place top grate back into position. Now follow step 8, page 20.

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

Thermocouple

Pilot Burner

Thermocouple

Pilot Burner

Figure 24 - Correct Pilot

Figure 25 - Incorrect Pilot

Flame Pattern

Flame Pattern

If pilot flame pattern is incorrect, as shown in Figure 25

turn heater off (see To Turn Off Gas to Appliance, above)

see Troubleshooting, pages 22 through 25

104025

21

Page 21
Image 21
Desa SCIVFR Inspecting Burners, To Turn Off Gas To Appliance, Manual Lighting Procedure, Operating Heater, Continued