INSTALLING
8
NOTICE
A qualified service person must install heater. Follow all local codes.
NOTICE
State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes.
WARNING
WARNING ICON | G 001 |
Never install the heater
•in a bedroom or bathroom
•in a recreational vehicle
•where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater
•in high traffic areas
•in windy or drafty areas
CAUTION
WARNING ICON | G 001 |
This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities in the air (such as tobacco smoke) exist, may discolor walls.
IMPORTANT:
CHECK GAS TYPE
Use only propane gas. If your gas supply is not propane, do not install heater. Call dealer where you bought heater for proper type heater.
CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)
WARNING
WARNING ICON | G 001 |
Maintain the minimum clearances. If you can, provide greater clear- ances from floor, ceiling, and adjoining side and back walls.
Carefully follow the instructions below. This stove is a freestanding unit designed to set directly on the floor. IMPORTANT: You must maintain minimum wall and ceiling clearances during installation. The minimum clearances are shown in Figure 4, page 9. Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 4)
A.Clearances from outermost point of stove top to any combustible side wall should not be less than 12 inches.
B.Clearances from outermost point of stove top to any combustible back wall should not be less than 6 inches (Includes Corner Installations).
C.Clearances from the stove top to the ceiling should not be less than 48 inches.
104025