INSTALLATION
Continued
INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION
Note: When used as a vented decorative, appliance must be installed only in a
If your heater is a
1.The fireplace does not meet the clearance to combustibles requirements for
2.State or local codes do not permit
3.You prefer vented operation.
If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 27). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.
Damper | Damper |
Clamp |
Damper
Clamp
Damper
See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be
maintained at all times. |
|
Area of Various Standard Round Flues | |
Diameter | Area |
5" | 20 sq. inches |
6" | 29 sq. inches |
7" | 39 sq. inches |
8" | 51 sq. inches |
Chimney Height | Minimum Permanent |
| Flue Opening |
6' to 15' | 39 sq. inches |
15' to 30' | 29 sq. inches |
INSTALLING REMOTE CONTROL | |
ACCESSORY BRACKET | |
If installing optional remote control accessory you | |
will need to install the remote accessory bracket | |
for the receiver. |
|
Use screws provided to attach bracket to valve | |
bracket as shown in Figure 11. | |
Follow installation instructions included with | |
remote accessory. |
|
Valve Bracket |
|
Remote |
|
Bracket |
|
Figure 11 - Attaching Remote Bracket to
Valve Bracket
Masonry Manufactured
FireplaceFireplace
Figure 10 - Attaching Damper Clamp
12 | www.desatech.com |