Desa SMA24VPA, SMA18VNA, SBJ24VPA, SBJ18VNA WARNING If you smell gas Shut off gas supply

Models: SBJ24VPA SMA24VPA SMA18VNA SBJ18VNA

1 32
Download 32 pages 38.9 Kb
Page 25
Image 25
 WARNING: If you smell gas

TROUBLESHOOTING

Continued

Manual background WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

Heater produces unwanted

1. Heater burning vapors from

1.

Open window to ventilate

odors

 

paint, hair spray, glues, clean-

 

room. Stop using odor caus-

 

 

ers, chemicals, new carpet,

 

ing products while heater is

 

 

etc. (See IMPORTANT state-

 

running

 

 

ment above)

2.

Refill supply tank (propane/LP

 

2.

Low fuel supply (propane/LP

 

 

only)

 

only)

 

3.

Gas leak. See warning state-

3.

Locate and correct all leaks (see

 

 

ment at top of page

 

Checking Gas Connections,

 

 

 

 

page 14)

 

 

 

 

Heater shuts off in use (ODS

1. Not enough fresh air is avail-

1.

Open window and/or door for

operates)

 

able

 

ventilation

 

2.

Low line pressure

2.

Contact local natural or pro-

 

3.

ODS/pilot is partially

 

pane/LP gas company

 

3.

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 21)

 

 

 

 

Gas odor even when control knob

1. Gas leak. See warning state-

1.

Locate and correct all leaks

is in OFF position

 

ment at top of page

 

(see Checking Gas Connec-

 

2.

Control valve or gas control

 

tions, page 14)

 

2.

Replace control valve or gas

 

 

defective

 

control

 

 

 

 

Gas odor during combustion

1. Foreign matter between con-

1.

Take apart gas tubing and

 

 

trol valve and burner

 

remove foreign matter

 

2.

Gas leak. See warning state-

2.

Locate and correct all leaks (see

 

 

ment at top of page

 

Checking Gas Connections,

 

 

 

 

page 14)

Log set cycles to pilot, but room temperature drops to a lower than ideal level before log set comes back on

1.Hand-held remote control is too close to heater

1.Move hand-held remote con- trol unit farther away from the heater