Desa AND SPC-54PHT owner manual Check for Leaks, Pole and BURNER/CONTROL Assembly

Models: AND SPC-54PHT SPC-54PHW, SPC-54PHB, SPC-54PHT

1 12
Download 12 pages 26.65 Kb
Page 6
Image 6

ASSEMBLY INSTRUCTIONS

Continued

CHECK FOR LEAKS

IMPORTANT: The heater must be leak tested be- fore any further assembly is done. Use only a soap and water solution. DO NOT USE FLAME.

Turn control knob to the "OFF" position. Securely connect regulator to propane/LP gas cylinder. Open propane/LP cylinder valve. Apply a soap and water solution to connections at the manifold, burner, and control assembly. Bubbles forming show a leak. In case of any leaks, turn off pro- pane/LP cylinder valve, remove manifold, check and clean connection. Reconnect manifold and leak test again.

Upon completion of leak test, and when there is no sign of a leak, turn off propane/LP cylinder valve and disconnect regulator from propane/LP gas cylinder. Remove propane/LP gas cylinder and continue to next step.

POLE AND BURNER/CONTROL ASSEMBLY

Attach pole to burner and control assembly (see Figure 6). Align the three holes. Insert a small bolt in each hole and tighten using #2 Philips head screwdriver.

MANIFOLD FIXING PLATE AND POLE SUPPORT

1.Locate threaded hole underneath post support. This hole is for mounting manifold fixing plate (see Figure 7).

2.Align holes on manifold fixing plate with threaded holes on pole support.

3.Make sure manifold fixing plate is facing downward see (Figure 7).

4.Use a medium bolt to tighten manifold fixing plate to post support using #2 Philips head screwdriver.

5.Turn manifold fixing plate so it will hold manifold in place.

6.Tighten medium bolt so manifold fixing plate will not move.

Manifold

Fixing Plate

Figure 7 - Attaching Manifold Fixing

Plate to Post Support

Figure 6 - Attach Burner and Control

Assembly to Pole

6

www.desatech.com

114144-01B

Page 6
Image 6
Desa AND SPC-54PHT owner manual Check for Leaks, Pole and BURNER/CONTROL Assembly, Manifold Fixing Plate and Pole Support