Desa UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE Installing Gas Piping To Fireplace Location

Models: UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE

1 40
Download 40 pages 30.79 Kb
Page 15
Image 15
•raise the mantel to an acceptable height, OR

INSTALLING Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance between Continued mantel shelf and top of fireplace opening.

Mantel Shelf

10"

8"

6"

2 1/2"

20"

/2"

/2"

30"

24

27

 

1

1

 

Figure 15 - Minimum Mantel Clearances for Built-In Installation

If your installation does not meet the above minimum clearances, you must:

raise the mantel to an acceptable height, OR

remove the mantel.

INSTALLING GAS PIPING TO FIREPLACE LOCATION

NOTICE

A qualified service person must connect fireplace to gas supply. Follow all local codes.

CAUTION

WARNING ICON

G 001

Never connect heater directly to the propane supply. This heater requires an external regulator (not sup- plied). Install the external regulator between the heater and propane supply.

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by

sediment trap

 

installer, see Figure 16, page 16)

tee joint

piping (check local codes)

pipe wrench

sealant (resistant to propane gas)

approved flexible gas line with

manual shutoff valve *

 

gas connector (if allowed by

test gauge connection *

 

local codes) (not provided)

*An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories, page 32.

Continued 15

101969

Page 15
Image 15
Desa UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE Installing Gas Piping To Fireplace Location, remove the mantel, Continued