TROUBLE- |
|
|
|
| WARNING ICONG 001WARNING |
|
|
|
|
SHOOTING |
|
|
| If you smell gas |
|
|
|
| |
Continued |
|
|
| • Shut off gas supply. |
|
|
|
| |
|
|
| • Do not try to light any appliance. |
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
| • Do not touch any electrical switch; do |
|
| |||
|
|
|
| not use any phone in your building. |
|
| |||
|
|
|
| • Immediately call your gas supplier from |
|
| |||
|
|
|
| a neighbor’s phone. Follow the gas |
|
| |||
|
|
|
| supplier’s instructions. |
|
|
|
| |
|
|
|
| • If you cannot reach your gas supplier, |
|
| |||
|
|
|
| call the fire department. |
|
|
|
| |
|
|
|
|
|
|
| |||
| IMPORTANT: Operating fireplace where impurities in air exist may create odors. | ||||||||
| Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new | ||||||||
| carpet or textiles, etc., create fumes. These fumes may mix with combustion air and | ||||||||
| create odors. These odors will disappear over time. |
|
|
|
| ||||
|
|
| OBSERVED | POSSIBLE |
|
|
|
| |
|
|
| PROBLEM | CAUSE | REMEDY | ||||
|
|
|
|
|
|
| |||
|
|
| Fireplace produces a | 1. Metal expanding while | 1. This is common with | ||||
|
|
| clicking/ticking noise | heating or contracting |
| most fireplaces. If noise | |||
|
|
| just after burners are | while cooling |
| is excessive, contact | |||
|
|
| lit or shut off |
|
| qualified service person | |||
|
|
|
|
|
|
| |||
|
|
| Fireplace produces | 1. Fireplace burning va- | 1. Open window and | ||||
|
|
| unwanted odors | pors from paint, hair |
| ventilate room. Stop | |||
|
|
|
|
| spray, glues, cleaners, |
| using odor causing | ||
|
|
|
|
| chemicals, new carpet, |
| products while fireplace | ||
|
|
|
|
| etc. (See IMPORTANT |
| is running | ||
|
|
|
|
| statement above) |
|
|
|
|
|
|
|
|
| 2. Gas leak. See Warn- | 2. Locate and correct all | |||
|
|
|
|
| ing statement at |
| leaks (see Checking Gas | ||
|
|
|
|
| top of page |
| Connections, page 18) | ||
|
|
|
|
|
|
|
| ||
|
|
| Fireplace shuts off in | 1. Not enough fresh air is | 1. | Open window and/or | |||
|
|
| use (ODS operates) | available |
| door for ventilation | |||
|
|
|
|
| 2. Low line pressure | 2. | Contact local propane | ||
|
|
|
|
|
|
| gas company | ||
|
|
|
|
| 3. ODS/pilot is partially | 3. | Clean ODS/pilot (see | ||
|
|
|
|
| clogged |
| Cleaning and Mainte- | ||
|
|
|
|
|
|
| nance, page 26) | ||
|
|
|
|
|
| ||||
|
|
| Gas odor even when | 1. Gas leak. See Warn- | 1. Locate and correct all | ||||
|
|
| control knob is in | ing statement at |
| leaks (see Checking Gas | |||
|
|
| OFF position | top of page |
| Connections, page 18) | |||
|
|
|
|
| 2. Control valve defective | 2. | Replace control valve |
Continued