Desa UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE Technical Service Service Hints, Trouble Shooting

Models: UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE

1 40
Download 40 pages 30.79 Kb
Page 30
Image 30
TECHNICAL SERVICE

TROUBLE-

SHOOTING

Continued

TECHNICAL SERVICE

SERVICE

HINTS

30

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Gas odor during

1.

Foreign matter be-

1.

Take apart gas tubing

combustion

 

tween control valve

 

and remove foreign

 

 

and burner

 

matter

 

2.

Gas leak. See Warn-

2.

Locate and correct all

 

 

ing statement at

 

leaks (see Checking Gas

 

 

top of page 29

 

Connections, page 18)

 

 

 

 

 

Moisture/condensation

1.

Not enough combus-

1.

Refer to Air for Com-

noticed on windows

 

tion/ventilation air

 

bustion and Ventilation

 

 

 

 

requirements (page 6)

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564).

When gas pressure is too low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burners will produce flames and soot

fireplace will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

101969

Page 30
Image 30
Desa UNVENTED (VENT-FREE) PROPANE GAS FIREPLACE Technical Service Service Hints, Trouble Shooting, Continued